Page 4
www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
Page 5
WARNING TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. CAUTION To reduce risk of fire and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. Not for use over an outdoor grill. OPERATION Always leave safety grilles and filters in place.
Page 7
Equivalent number Equivalent number Duct pieces Duct pieces T otal length x used length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
Page 8
www.zephyronline.com DUCTING A minimum of 6” round duct must be used to maintain maximum air flow efficiency. Always use rigid type metal ducts only. Flexible ducts could restrict air flow by up to 50%. x . C Use calculation worksheet to compute total duct work (Page 5).
WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape.
Page 10
www.zephyronline.com ” ” STANDARD min. ducted - 27” ” 5/16 min. recirc. - 31” max. - 48” Z1C-00AN, Z1C-00ANBS ” EXTENSIONS 7/16 min. ducted - 43” min. recirc. - 47” max. - 81” , 35 ” 15/16” 7/16 ” 1/16 1"...
Page 11
” 9” STANDARD min. ducted - 28” min. recirc. - 32” max. - 45” Z1C-01SA, Z1C-01SAB Z1C-01SAW, Z1C-01SABS EXTENSIONS min. ducted - 46” min. recirc. - 50” max. - 80” ” , 35 ” 15/16” 7/16 1” 1/2”...
Page 12
www.zephyronline.com 10 3/8” 10 9/16” STANDARD min. ducted - 23” min. recirc. - 27 1/2” max. - 42 1/2” Z1C-00RV, Z1C-00RVBS min. ducted - 41” min. recirc. - 46” max. - 80” 23 15/16” 13 3/4” 29 15/16, 35 3/16” 19 3/4”...
Page 13
11” ” STANDARD min. ducted - 26 1/2” min. recirc. - 30 1/2” max. - 47 1/2” Z1C-00RO EXTENSION min. ducted - 41” min. recirc. - 45” max. - 77” , 35 ” ” 15/16” 7/16 1/16 5 5/8” 2 5/8”...
Page 14
www.zephyronline.com CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A. (26” minimum from range top) 2. Plum and mark center line. 3.
Page 15
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and filtered by a set of optional charcoal filters. The air is then purified and re- circulated back within the home.
Page 16
www.zephyronline.com Power / Delay Off Adjust 5 Speed Levels Lights On/Dim/Off Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at.
Page 17
3 LIGHTS BUTTON - Lights are two levels, High and Low. - From off, press one time for High. Press again for Low. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters.
Page 18
www.zephyronline.com SURFACE MAINTENANCE: Do not use corrosive detergents, abrasive detergents or oven cleaners. Do not use any product containing chlorine bleach or any product containing chloride. Do not use steel wool or abrasive scrubbing pads which will scratch and damage surface. Cleaning Stainless Steel Clean periodically with warm soapy water and clean cotton cloth or micro fiber cloth.
Some local codes limit the maximum amount of CFM a range hood can move. ACT allows you to control the maximum blower CFM of select Zephyr Ventilation range hoods without the need for expensive make up air kits. ACT enables the installer to easily set the maximum blower speed to one of two most commonly specified CFM levels;...
Page 20
www.zephyronline.com ZAN, ZSA, ZRV, ZRO Power consumption shown for default CFM blower configuration ACT 390 CFM - Fan Max. @ 2.3A ACT 290 CFM - Fan Max. @ 1.9A...
TROUBLESHOOTING PROCEDURES Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
Need help?