Quick Links

TROUBLE SHOOTING YOUR LIFT
These tips might save you a service call. Make sure
you remove power from the lift before attempting any
of the following items.
1. Lift not running, steel cable not tight.
A "slack cable" safety device stops the lift from running if any slack is
sensed in the cable. To reset the device, do the following: Remove the
round plastic hole cover in the side of the lift facing uphill. Insert the
handcrank tube onto the pulley and turn clockwise until the cable is fully
wound tightly on the drum and the lift begins coming up the track. A loud
click will occur indicating the safety device has been reset. The lift should
now run.
If the lift is not all the way at the bottom of the track, an alternative method
for resetting the slack cable device may be used. Half way between the
lift and top of the track, grasp the steel cable and lift it straight up in the air
(as if you were pulling on a bow string) until you are holding the weight of
the lift. Slowly lower the cable back down to the track, the lift will travel
down the track and the cable will now be tight.
2. Lift all the way at top of track— unit won't run.
The lift hit the final limit switch—meaning it has run too far up. Remove
the round plastic hole cover in the side of the lift facing uphill. Insert the
handcrank tube onto the pulley and turn counter-clockwise 4-5 turns until
the lift moves down the track about 1". Slide the final limit actuator (metal
tab sticking up off the track) down until it touches the lift. The lift should
now run. Lower the top switch cam about 1/2" to keep problem from
recurring.
Manufacturer for AmeriGlide by
Summit Lifts, Inc.
18505 E. 163rd St.
Lake Winnebago, MO 64034
Phone 816-537-0611
E-mail info@summitlifts.com
www. summitlifts.com
Toll Free Phone 866-378-6648
AmeriGlide
OWNER'S MANUAL
Rubex Stair Lift
• Warranty Details
• Proper Use of Your Lift
• Ideas to Keep Your Lift Problem Free
• Safety Tips
• Troubleshooting Problems
NOTE:
IT IS IMPORTANT THIS ENTIRE MANUAL BE
READ AND UNDERSTOOD BEFORE ATTEMPTING
TO OPERATE THIS LIFT. IF THERE IS ANYTHING IN
THIS MANUAL YOU DO NOT UNDERSTAND
CLEARLY, CONTACT YOUR DEALER FOR CLARIFI-
CATION BEFORE YOU OPERATE THIS LIFT, OR
CALL US TOLL FREE AT 866-378-6648 BEFORE
YOU OPERATE THIS LIFT.
Revised: September 2010

Advertisement

loading

Summary of Contents for AmeriGlide Rubex Stair Lift

  • Page 1 A “slack cable” safety device stops the lift from running if any slack is sensed in the cable. To reset the device, do the following: Remove the Rubex Stair Lift round plastic hole cover in the side of the lift facing uphill. Insert the handcrank tube onto the pulley and turn clockwise until the cable is fully wound tightly on the drum and the lift begins coming up the track.
  • Page 2 3 years from the Date Purchased date of original purchase of the unit. AmeriGlide, Inc. and its dealers shall not be liable for any consequential, special or incidental damages arising out of the purchase or use of the unit or resulting from the breach of this Limited Warranty, or any implied warranty.
  • Page 3: Troubleshooting

    SAFET Y T IPS T A B L E O F C O N T E N T S Customer Information Sheet Have the dealer adjust the footrest and seat back • height so it fits you properly. Operate the lift while the dealer is present. Be •...
  • Page 4 USING YOUR AMERIGLIDE RUBEX STAIR LIFT KEEPING YOUR STAIR LIFT This lift will provide you years of service when used TROUBLE FREE TROUBLE FREE AND SAFE correctly. Make sure you understand each of the features listed below prior to using your stairway lift.