Section 6
QF2300
Automatic Shut-Off
An 8 minute lockout starts when the
compressor de-energizes. When the
ice drops away from the bin level
probe the ice machine will begin an
initial start-up cycle, provided the "8
minute lockout" has expired.
8 Minute Lockout
The bin level light will flash until the 8
minute lockout expires. After the 8
minute lockout time can be
overridden by moving the ON/OFF/
CLEAN toggle switch for ICE to OFF
and back to ICE.
Toggle Switch
Bin Level Probe
Control Board Relays
#1
Liquid Line Solenoid Valve
#2
Dump Valve
#3
Gear Motor
#$
Water Float Valve Solenoid Coil
Part No. 80-1214-3
GROUND
L1
(25)
(51)
Automatic Shut-Off (Until Ice No Longer Contacts Bin Level Probe)
Revised 8/2003
RELAY
(91)
K2
RELAY
K1
7 AMP
FUSE
(65)
RELAY
RELAY K4
K3
WATER FLOAT
VALVE
(52)
(22)
DUMP VALVE
Electrical System
C1
C2
LIQUID LINE
SOLENOID
(54)
(53)
EQUALIZATION
SOLENOID
(58)
CENTRIFUGAL
SWITCH
INTERNAL
OVERLOAD
START
RUN
GEARMOTOR
(56)
(55)
ICE
CLOSED ( Ice Contacting probe)
OFF
OFF
OFF
OFF
L2
(57)
(22)
SV2113
6-35