Section 3
Water Reservoir Cover Removal
QF2300
1. Place the toggle switch in the OFF position, turn off
the water supply and disconnect electrical power to
the ice machine.
2. Remove water level probes.
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. Remove top cover from float reservoir.
2
QF2300 Shown
Part Number 80-1214-3
Float Valve Removal
1. Place the toggle switch in the OFF position, turn off
2. Disconnect water supply line at float valve quick
3. Remove water float valve coil.
4. Depress coil and rotate 1/4 turn counterclockwise.
5. With coil wires attached, lift coil off enclosure tube.
6. QF0800/QC0700/QF2300 ONLY Rotate quarter turn
7. QF0800/QC0700 ONLY Remove cotter key and pin
3, 4, 5
8. Remove top cover from float reservoir.
9. Lift float valve out of float reservoir.
6
SV1791
Ice Machine Operation
the water supply and disconnect electrical power to
the ice machine.
disconnect by depressing stainless steel lever.
fasteners counterclockwise.
from ice chute.
FLOAT VALVE