Section 6
Automatic Shut-Off
An 8 minute lockout starts when the
compressor de-energizes. When the
ice drops away from the bin level
probe the ice machine will begin an
initial start-up cycle, provided the "8
minute lock-out" has expired.
8 Minute Lock-out
The bin level light will flash until the 8
minute lock-out expires.
After the 8 minute lock-out expires
the bin level light will de-energize.
The 8 minute lock-out time can be
overridden by moving the ON/OFF/
ICE toggle switch from ICE to OFF
then back to ICE.
Toggle Switch
Bin Level Probe
Control Board Relays
#1
Contactor Coil
Compressor
Condenser Fan Motor
#2
Dump Valve
#3
Gear Motor
#4
Water Float Valve Solenoid Coil
Part No. 80-1214-3
L1
GROUND
(51)
Automatic Shut-Off (Until Ice No Longer Contacts Bin Level Probe)
Revised 8/2003
(21)
RELAY
K2
RELAY
K1
10 AMP
FUSE
(25)
RELAY
RELAY K4
K3
WATER FLOAT
VALVE COIL
(56)
(52)
(22)
(55)
DUMP VALVE
COIL
L1
T1
(41)
CONTACTOR
CONTACTS
RUN
Electrical System
HIGH
CONTACTOR
PRESSURE
COIL
CUT-OUT
(90)
(95)
GEARMOTOR
(46)
(47)
GEARMOTOR
RUN CAPACITOR
FAN MOTOR
(AIR-COOLED ONLY)
(10)
(11)
(14)
START
(44)
ICE
Closed (Ice Contacting Probe)
Open / OFF
OFF
OFF
OFF
OFF
OFF
L2 (N)
(65)
(43)
(48)
SV3039
6-9

Advertisement

Table of Contents
loading

Table of Contents