ESPRIT 727 CONNECTION DIAGRAM
BLACK
RED
+
RECHARGEABLE
BATTERY
KEY SWITCH CONNECTIONS
READY
ARMED
220W
KEY SWITCH
EOL
ESPRIT 727 Version 3.1 Upgrade Information
1- Programming addresses are no longer used when creating master and user codes. Press code
number, and enter code value
2- The installer code has no access to "arm", "disarm" or "bypass" functions, and cannot be used
for user code programming.
3- "Follow" zone definition has been added at address
4- Zone 7 ("fire" zone can be defined as "fire" or "24 hour" zone and displays it in memory as zone 7.)
5- The relay can be programmed to energize or de-energize upon alarm. (Fail-safe operation)
(Address "
37
", key
6- Fire alarms will shut off once the programmed alarm period has expired.
7- Key
[10]
can now be programmed to activate "regular" or "stay" arming. (Key
follows keyswitch definition.) If the panel is "stay" armed, and key
[10]
will provide an exit delay.
8- Alarm memory will not be erased upon system arming. Most recent alarm event is displayed first
on the keypad. Panic is not displayed in memory.
9- Keypad buzzer follows bell output.
10- Arm LED (red) on keypad flashes upon any alarm.
11- After using the keyswitch to arm or disarm the panel, the keyswitch must be disengaged in order
to perform the next operation.
12- Versions
1.0
and
2.0
BATT
5 AMP
VR 1
BATT
+
COM
N.C.
N.0.
RELAY
/
BELL
PGM
active = short
-
+
to ground
BELL
SIREN
16.5VAC 40VA
Fuse at 3A
AUX +
PGM 2
PGM 1
KYPD GRN
KYPD BLK
[5]
.)
hardware can be upgraded to Version
MADE IN
CANADA
U3
+
AUX AUX AUX AUX
GRN YEL
Z1
16VAC
KEYPAD
N.C.
Z1
EOL EOL
N.O. N.O.
TRANSFO
A.C.
ZONE
POWER
8
N.C.
N.O.
EOL
AUX POWER
RMED
400 mA MAX.
PS1
ESPRIT
arming / panic
module
34
.
[10]
is enabled, pressing key
3.0
by replacing the processor.
6
U5
+
U6
U4
FIRE
Z2
Z3
Z4
Z5
Z6
COM
COM
COM
24
N.C.
Z2
EOL EOL
N.O. contacts
Smoke and heat detector
YEL
GRN
BLK
RED
TAMPER
*KEYPAD
max 5 per system
(
PS1
is considered as keypad)
RE DY
must be reduced by 20mA.
*For each additional keypad the auxiliary supply
Version 2.0
programmed
via addresses
installer code has
access to all operations
not available
fire zone definition only
energize on
alarm only
continuous alarm
[10]
definition
no exit delay upon
"stay" arming
alarm memory erased
upon system arming
not available
not available
engaged keyswitch alter-
nates between arm/disarm
Paradox Security Systems Graphic Dept. - PRINTED IN CANADA - 960606
EOL
RES
Keypad
ZONE #8
jumper
must
EOL
be "on"

Advertisement

loading