Key Dimensions; Location Requirements; Choose The Proper Location - Kenmore 796.9128 Series Use & Care Manual

Hide thumbs Also See for 796.9128 Series:
Table of Contents

Advertisement

Available languages

Available languages

KEY DiMENSiONS
AND SPECiFiCATiONS
Description
Dryer (Gas and Electric)
Electrical Requirements
Refer to the rating label
Gas Requirements _ NG:
4-10.5
inches WC (Water Column)
Gas Requirements _ LP:
8-13 inches WC
Dimensions
27 in. (W) X 30 1/4 in. (D) X 38 in. (H), 51 3/16 in. (D with door open)
68.6 cm (W) X 76.7 cm (D) X 96.5 cm (H), 130 cm (D with door open)
Net Weight
Electric : 147 lb. (66.7 kg) Gas : 150.5 lb. (68.3 kg)
Drying Capacity
IEC 7.3 cu. ft.
_Gas Models Only
LOCATION
REQUIREMENTS
Standard
Installation
- Side View
iMPORTANT:
Read att installation
instructions
completely
before
installing and operating
your dryer.
it is important
that you review this entire manual
before
22 1/2in.
installing and using your dryer, it contains detailed
(57.3 cm)
instructions concerning
electrical
connections,
gas
connections
and exhaust requirements.
CHOOSE
THE PROPER LOCATION
* Store and install the dryer where it will not be exposed
to temperatures
below freezing
or exposed to outdoor
weather
conditions.
* Choose a location
with a solid, level floor.
*If the dryer is being installed in a garage,
place the
dryer at least 18 inches (45.7cm)
above the floor.
* Properly ground the dryer to conform
with all
governing
codes and ordinances.
* To reduce the risk of electric
shock, do not install the
dryer in damp or wet locations.
iMPORTANT:
If you are installing
your
dryer
in a
manufactured
or mobile
home,
please
refer
to the
Special
Electrical
Requirements
for Mobile
or
Manufactured
Homes
section.
CLEARANCES
* Most installations
require a minimum 5 1/2 inch (14 cm)
clearance
behind the dryer for the exhaust ducting.
* Allow minimum
clearances
of at least 1 inch (2.5 cm)
on the sides and back to minimize vibration
and noise.
* Allowing
additional
clearance
for installation
and
servicing
is recommended.
* Be sure to allow for wall, door, or floor moldings that
may increase the required
clearances.
* Allow at least 21 inches (53.3 cm) in front of the dryer
to open the door.
Standard Installation - Front View
DI!
_"_JJ_
30 1/4 in. _-
J_
4 in.
0 cm)
(76.7 cm) _
(10 cm)
52 t/4 in.
(132.7 cm)
1 in.
(2.5 cm)
l in.
27 in.
(2.5 cm)
(68.6 cm)
3"
(7.6 cm)
Vent
.-
48 sq. in.
(310 sq. cm.)
Vent
24 sq. in.
(155 sq. cm.)
Y
3"
_
(7.6 cm)
J
1
Addltional instructions for closet installations:
The closet door must allow for sufficient airflow. Refer to the
diagram
above for minimum vent opening requirements. A
louvered door is also acceptable.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

796.8128 series796.8118 series796.9118 series

Table of Contents