Side View
I
I
I
A. Drain hose
B. 1" (2.54 cm) air gap
C. PVC drain reducer
2"-11/2"
(5 cm - 3.8 cm)
D. Center of drain should be 23" (58.4 cm) from
front of door, with or without the _" (1.91 cm)
panel on the door. The drain should also be
centered from left to right (7_/'
[18.56 cm]
from either side of the ice maker).
Drain Pump System
(on some models)
IM PORTANT:
Connect the ice maker drain to your drain in accordance
with
the International
Plumbing Code and any local codes and
ordinances.
The drain pump discharge line must terminate at an open
sited drain.
Maximum rise 10 ft (3.1 m)
Maximum run 100 ft (30.5 m)
NOTES:
If the drain hose becomes twisted and water cannot drain,
your ice maker will not work.
It may be desirable to insulate the drain line thoroughly up to
the drain inlet. An Insulation Sleeve kit, Part Number
W10365792,
is available for purchase.
Do not connect the outlet end of the drain tube to a closed
pipe system to keep drain water from backing up into the ice
maker.
Connecting
the Drain
After ensuring that the drain system is adequate, follow these
steps to properly place the ice maker:
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
1. Plug into a grounded 3 prong outlet.
Excessive
Weight Hazard
Use two or more people to move and install
ice maker.
Failure to do so can result in back or other injury.
2. Style 1--For gravity drain system, push the ice maker into
position so that the ice maker drain tube is positioned over
the PVC drain reducer. See "Gravity Drain System."
Style 2--For drain pump system connect the drain pump
outlet hose to the drain. See "Drain Pump System."
3. Recheck the ice maker to be sure that it is level. See
"Leveling."
4. If it is required by your local sanitation code, seal the cabinet
to the floor with an approved caulking compound
after all
water and electrical connections
have been made.
©oo
Reversa Side
Swing
Only
Tools Needed
Gather the required tools and parts before starting installation.
5/le" wrench
Flat putty knife
1/4"wrench
Phillips screwdriver
Hinge pin
5_6" hex-head hinge screw
Handle screw
End cap screw