Performance Data Sheet - GE GSHS6KGZCCSS Owner's Manual And Installation

Table of Contents

Advertisement

Available languages

Available languages

Performance Data Sheet
(on somemodels)
SmartWater
Filtration System-GE ® MSWF Cartridge
This system has been tested and certified in filter model GE HSWF according
to NSF/ANSI Standards 42 and 53 for reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water entering
the system was reduced to a concentration
less than or equal tothe permissible
limit for water
leaving the system, as specified
in NSF/ANSI Standards 42 and 53.* (Safety factors built in for unmetered
usage.)
Standard
No, 42: Aesthetic
effects
,
influent Challeng e
Effluent
% Reduction
'
Parameter
'
USEPAMCL
Concentration
'
Average
Maximum
'
Average
Maximum
Min. Required Reduction
-
2.0 mg/L ± 10%
0.06 mg/L
0.i0 mg/L
97%
9.1%
> 50%
-
at least 10,000particles/
408,333
670,000
95.5%
89.4%
> 85%
.............................................................................................
mL
Standard
No. 53: Health
effects
Influent Challenge
Effluent
% Reducti0n
Max. Permissible
Parameter
'
USEPAMCL
Concentration
Average
Maximum
Average
Maximum
Product Water
1 NTU ....
99.95% Reduction
0.010 mg!L
0.010 mg/L
0.002 mg/L
0.002 mg!L
0.0002 mg/L
0.003 mg!L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
11 ± 1 NTU ....
Hinimum 50,000 L
0.15 mg/L e 10%
0.15 mg/Le 10%
0.006 mg!L ± 10%
0.006 mg!L ± 10%
0.002 mg/L ± 10%
0.009 mg/L ± 10%
0.210 mg!L ± 10%
0.015 rag/L± 10%
0.015 mg/L± 10%
0.080 mg/L ± 10%
0.225 mg/L ± 10%
107 to t0 8fibers/L;
fibers> 101_m in length
*Tested using pressure of 60 psig; pH of 7.5 ± 0.5; temp of 680 + 5°F (20° + 2.5°C).
**Heasurement
in Particles/mL
Particles used were 0.5-1 microns.
***Based on the use of Cryptosporidium
parvum oocysts.
....
NTU=Nephelometric
Turbidity Units
0.38 NTU
< i #/L
< i ppb
3.1 ppb
0.34 ppb
0.66 ppb
< 0.02 ppb
< 0.5 ppb
7.7 ppb
<ippb
< 0.5 ppb
< i ppb
< 0.5 ppb
< 0.17 HF/L
Capacity 300gallons(1,135liters).Contaminant reduction determinedby NSF testing.
0.5 NTU
4 #/L
< 1 ppb
9.0 ppb
O.7ppb
1.5 ppb
<0.02 ppb
< 0.05 ppb
35ppb
< i ppb
< 0.5 ppb
i ppb
< 0.5 ppb
< 0.17 MF/L
96.5%
> 99.99%
99.3%
98.0%
94.0%
88.4%
>99.0%
>93.9%
96.0%
> 92.9%
> 96.8%
>98.7%
>99.7%
>99%
95.4%
>99.99%
99.3%
95.5%
89.6%
73.7%
> 99.0%
>94.3%
82.0%
>92.9%
>97.0%
> 98.7%
>99.8%
>99%
0.5 NTU
99.95%
0.010 mg/L
0.010 mg!L
0.002 mg!L
0.002 mg!L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application
Guidelines/Water
Supply
Parameters
Service Flow
10.9 gpm (3.14Ipm)
................................................................
Water Pressure
Water Supply
[ P_e_/cliei
......................................................................................................................................................................
Water Temperature
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
Seeinsert for Warranty information.
Operating
Specifications
• Pressure requirement:
40-120 psi (2.8-8.2 bar), non-shock
• Temperature: 33-100°F (0.6-38°0
• Flow rate: 0.9 gpm (3.14 Ipm)
General
Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 4-1/2 gallons (about five minutes) to purge
trapped air
• Replace cartridge when flow becomes too slow.
, Protect from freezing by removing
filter cartridge
when temperatures
are
expected
to drop below 40°F (4.4°C). Do not install systems in areas where
ambient temperatures
may go above IO0°F or below 40°E Do not install
on a hot water supply.
Special
Notices
• Installation
instructions
are included with the product when shipped.
• This drinking water system must be maintained according to manufacturer's
instructions,
including replacement of filter cartridges.
• Do not use with water that is microbiological@ unsafe or of unknown quality with-
out adequate disinfection
before or after the system. Systems certified for cyst
reduction
may be used on disinfected water that may contain filterable cysts.
• The contaminants
or other substances removed or reduced by this water
treatment
system are not necessarily in your water.
• Check for compliance
with the applicable state and local laws and regulations.
• Note that while the testing was performed under standard laboratory
conditions,
actual performance
may vary. Systems must be installed and operated
in
accordance with manufacturer's
recommended
procedures and guidelines.
• Installation and use MUST comply with all state and local plumbing codes. Do not
install if water pressure exceeds 120 psi. tf your water pressure exceeds 80 psi
(552 kPa),you should install a pressure-limiting
valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
• Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
For conditions of use, health claims certified by the California Department
of Public
Health, and replacements,
see performance
data sheet. California Department
of Public Health Certification
#06-1834. The contaminants
or other substances
removed or reduced by this water filter are not necessarily in all users' water.
Tested and CerLified by NSF International
against ANSI/NSF Standards
42 and 53 in model GE HSWF for the reduction
of:
Standard
No. 42: Aesthetic
Effects
-
Chemical
- Chlorine Taste and Odor
- Hechanical Filtration
- Particulate Reduction,Class I
GE
Appliances
Appliance Park
Louisville, KY 40225
geapptianceparts.com
Standard
No. 53: Health
Effects
- Chemical
Reduction
- Atrazine
Reduction
- Endrin Reduction
- Benzene and Carbofuran
Reduction
- 1,4 Dichlorobenzene
and
2,4-D Reduction
- Lead and Lindane Reduction
- Mercury and Toxaphene Reduction
Mechanical Filtration
- Cyst and Asbestos Reduction
..- ...
REPLACEPIENT
ELEPIENT
EPA #10350-HN-OO5
© 2010 General Electric Company
PC61577C
34

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents