SmartWater Filtration System
GSWF Cartridge
This systemhas been testedaccording to NSF/ANS142/53for reduction of the substances listed below
The concentrationof the indicated substancesin water entering thesystem was reduced to a concentration
less than or equal to thepermissible limit for water leaving the system, as specified in NSF/ANS/ 42_3.*
(100%safety factors built in for unmetered usage)
Pa]l-al_leter
(:hlorine
"I & ()
]:'arli( ulale**
Parameter
Turbidity
(Xqs
Le_d
at pH 6.5
Le_d
at pH 8.5
Lindane
Atrazine
USEPA
MCL
USEPA
Influent
Average
1.845 mgiL
143,333#imL
lnfluent
StmMard No. 42: Aesthetic Effects
Influent
Challenge
Collcentr;t|iOll
2.0 lngiL+10%
al leat
10J)00 pardcles/rnL
Stmldard
No. 5.'4: Health
Effects
[nfluent ChaJlenge
Eftluent
Effluent
Average
Maximmn
< 0.05 mgiL
tl.tl5 mg/L
29.83 #/mE
140 #/mE
% Reduction
Average
Mi_mnmn
> 97.20%
116.43%
99.98!',
99.91 ¢;,
_, Reduction
Min. Required
Reduction
> 50%
>85%
Min. Required
MCL
1 NT[ ***
99.95_ Reduction
0.015 lngiL
(1.015 mg/L
0.0002
lngit
0.003 mgiL
Average
10.3 NT[ **"
200,000
#iL
0.15 lngiL
(1.14 lngiL
(1.0216 rag/L
0.0{t8 mg/L
Concen|ratlon
l+l NT[ **"
Minimum 50,000 L
0.15 mg/L+10%
0.15 lng/L+10%
0.002 mgiL+l()!'i
{L(}09mgiL+lt1%
Average
0.10G NT[
0
< (}.001 lng/L
(}.(}0l mgiL
<0.00002 mgiL
< 0.002
lngiL
Maximlml
0.14 NT[
0
< 0.00l
lngiL
0.003
mg/L
< 0.00002
mgiL
< 0.002
lngiL
Average
98.97%
> q9.q9?i
> 99.3371
> qq.2971
9%O7%
> 76.12_:;
Mi_mnmn
Reduction
98.61%
0.5 NT[
> 99.995:;
> 99.9571
> 99.3'3_:;
0.01(1 lngiL
97.86%
0.010 lngiL
98.75%
0.0002 mgiL
> 66.67(A
0.003 lngiL
Testedusinga flow rate of O.5gpm;pressureof 6O psig pHof 7.5_+ 0,5;temp,0f68°_+ 5°F(20°_+3°C1
..... M easurementin Partic/es/m/. P artic/esusedwere0,5-1microns
NTU=Nephelometric Turbidity units
Operating Specifications
[] Capacity:
(ertified
for up to 750 gallons
(2,838 l); up to six months
[] Pressure
requirement:
40-120
psi (2.8-8.2
bar)
[] Temperature:
33-100°F
(0.6-38°(:)
[] Flow rate: 0.5 gpm
(1.9 lpm)
General/nstallation/Operetion/Maintenance
Requirements
[] Flush ne_,_ cartridge
at hdl flow for 3 minutes
to i_m'ge, out trapped
air.
[] Replace
cartridge
when
flow becomes
too slow.
Special Notices
[] Installation
instru(tions,
parts
and service
availabilit_
and standard
_<u'rant_
are included
_dth the product
when
shipped.
[] This drinking
water s)stem
must
be maintained
according
to Faanufhcturer's
instructions,
including
replacement
of filter
cartridges.,
[] Do not use with water
that is microbiologicall}
unsafe
or of unknox_n
qualit}
without
adequate
disinfection
before
or
after the sxstem.
Sxstems
certified
for Qst reduction
max be used on disinfected
water
that max contain
filterable
cxsts.
[] The contaminants
or other
substances
remoxed
or reduced
b} this water
treatment
sxstem
are not necessaril)in
}our
watel'.
[] Check
for compliance
with the state and
local laws and
regulations.
[] Note
that while the testing
was performed
under
standard
laboratorx
conditions
actual
performance
ma) va_). S) stems
must
be installed
and operated
in accordance
>dth manufhcturer's
recommended
procedm'es
and
guidelines.
System
tested
and c(rtifi(d
by NSF Inlernational
againsl
Standard
42 for th(
re(luction
of
chlorine,
taste
and odor,
particulate
Class ] and Slandard
53 for the
re(luclion
of" (:}'st,
lead,
Lindane,
Atrazine
and
mrbidily.
Malltlt;_ctlll-e(l
t()1-: (;ellel-al
Elecu-ic
(:Ollll)all},
Louisville,
KY 40225
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

25

Table of Contents