Install Range Hood - KitchenAid KVUB606DSS0 Installation Instructions And Use & Care Manual

30" (76.2cm) and 36" (91.4cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

Insta
RangeHoo8
1. Remove the grease filters. See the "Range Hood Care" section.
2. Remove foam shipping pad from behind the blower motor.
3. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
A
NOTE: If the wall cap is directly behind the vent connector, the
dampers in the connector and wall cap must not interfere.
Remove the vent connector
damper if they interfere.
A
C
4,
5,
A. Keyhole slot
Use 1/8"(3 mm) drill bit and drill 4 pilot holes as shown.
A
A. Drill pilot hole
Install the 4 - 4.5 x 13 mm mounting screws in pilot holes.
Leave about 1/4"(6.4 mm) space between screw heads and
cabinet to slide range hood into place.
\\\\\\\\\\
1/4"
(6.4 ram)
3.
4.
E
A. Top round vent
transition
B. Top round vent
transition mounting
screws (2)
C. Top vent knockout
D
D. Rear vent knockout
E. Rear rectangular
transition
knockout mounting screws (3)
F. Hinge pin
G. Rear rectangular
vent transition
Place range hood on its back.
Using a T10 Torx adapter, remove the 8 screws holding the
bottom panel assembly in place. Remove the bottom panel
assembly and set it aside.
Vent Connector
Installation
Determine whether the range hood will be installed using either a
top or rear vent connection.
Top Vent Connector
Installation
1. Remove the top vent knockout.
2. Attach the round vent transition damper using 2 vent
transition mounting screws.
3. Remove tape from damper flap
Rear Vent Connector
Installation
NOTE: For rear venting, the blower motor position must be
changed.
1. Remove the rear vent knockout.
2. Attach the rectangular vent damper (purchased separately,
see "Assistance
or Service" section to order) using 3 vent
transition mounting screws. Make sure the vent damper pivot
is nearest to the top back edge of the range hood.
E
¸¸
i
D
A. Blower motor cover
D. Bottom panels
plate
assembly
B. Blower motor cover
E. Bottom panels
plate mounting screws
assembly mounting
(4)
screws
C. Back of range hood
5. Disconnect
the blower motor electrical connector from the
electrical box connector.
6. Using a T10 Torx adapter, remove the 4 screws from the
motor cover plate. Remove the motor cover plate and set it
aside.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kvub600dss0

Table of Contents