Installation
Instructions
[]
CONNECTING
INLET HOSES
fan some models)
To produce steam, the dryer must connect to the cold
water supply. Since the washer must also connect to the
cold water, a "Y" connector is inserted to allow both inlet
hoses to make that connection at the same time.
NOTE: Use the new inlet hoses provided; never
use old hoses.
1. Turn the cold water faucet off. Remove the washer inlet
hose from the washer fill valve connector (cold).
2. Ensure the rubber fiat washer is in place and screw the
female coupling of the short hose onto the washer fill
valve connector. Tighten by hand until firmly seated.
3. Attach the female end of the "Y" connector to the mule
coupling of the short hose. Ensure the rubber fiat washer
is in place. Tighten by hand until firmly seated.
4. Insert the filter screen in the coupling of the washer's
inlet hose. If a rubber fiat washer is already in place
remove it before installing the filter screen. Attach this
coupling to one male end of the "Y" connector. Tighten
by hand until firmly seated.
5. Ensure the rubber fiat washer is in place and attach the
dryer's long inlet hose to the other male end of the "Y"
connector. Tighten by hand until firmly seated.
6. Ensure the rubber fiat washer is in place and attach
the other end of the dryer's long inlet hose to the fill
valve connector at the bottom of the dryer back panel.
Tighten by hand until firmly seated.
7. Using pliers, tighten all the couplings with an additional
two-thirds turn.
NOTE: Do not overtighten. Damage to the couplings may
result.
[]
CONNECTING
INLET HOSES Icont.)
8. Turn the water faucet on.
9. Check for leaks around the "Y" connector, faucet and
hose couplings.
WATER SUPPLY REQUIREMENTS
Hot and cold water faucets IvlUSTbe installed within 42 in.
(107 cm) of your washer's water inlet. The faucets MUST
be 3/4 in. (1.9 cm) garden hose-type so inlet hoses can
be connected. Water pressure MUSTbe between 10 and
120 pounds per square inch. Your water department can
advise you of your water pressure.
NOTE:A water softener is recommended to reduce buildup
of scale inside the steam generator if the home water
supply is very hard.
_SERVICING
WARNING-
LABEL ALL WIRES
PRIOR TO DISCONNECTION
WHEN
SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS
OPERATION AFTER SERVICING/
INSTALLATION.
For servicing phone numbers for replacement parts, and
other information, refer to Owner's Manual or visit our
Web site.
REGISTERYOUR NEW APPLIANCE TO RECEIVEANY
IMPORTANT PRODUCT NOTIFICATIONS.
Please go to www.GEAppliances.com
or mail in your
Product Registration
Card.
For questions on installation, call: 800.626.2000 (US)or
800-561-3344 (Canada).
9

Advertisement

loading