Installation
_] RECONNECTING
GAS
Listed connector
ANSI
Z2!.24
/ CSA 6.!0
1/8" NPT PIPE
NEW METAL
PLUG FOR
GAS
FLEXIBLE GAS
INLET PRESSURE
LINE CONNECTOR
ADAPTER
ELBOW
3/8" NPT
SHUT-OFF
PIPE SIZE
ITEMS NOT SUPPLIED
_AT
LEAST i/2"
Note: The connector and fittings ore designed for use
only on the original installution and ore not to be reused
for another uppliance or at another locution. Keep flare
end of adoptor free of grease, oil and thread sealant.
CAUTION:
Use odopters os shown,Connector
nutsmust notbe connecteddirectly
topipethreods.
APPLYPIPECOMPOUND
TOTHE ADAPTER AND
DRYER GASINLET,
TIGHTEN THE FLEXIBLE
GAS LINE USING TWO
ADJUSTABLE
WRENCHES.
Instructions
APPLYPIPECOMPOUND
TO ALL MALETHREADS.
TIGHTEN ALL CONNECTIONS
USING TWO ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
[-_ LEAK TEST
,& WARNING:
NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
\S VALVE.
._ckall connections
for leoks with soapy solution or equivalent.
)ly soop solution. Leok test solution must not contoin ommonio
ch could cGuse damage to the brass fittings. If leoks (]re found,
_evGIve, retighten the joint, Gnd repeot the soop test.