Before
calling for service,
review this list, It may save you time and expense,
This list includes
common
occurrences
that are not
the result
of defective
workmanship
or materials
in this appliance
OCCURRENCE
SOLUTION
Air conditioner
will not operate.
Air
from
unit
does
net
feel
cold
enough.
Wall plug disconnected. Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Control is OFR Turn Control ON and set to desired setting.
Room temperature below 60°F (16°C). Cooling may not occur until room temperature rises above
60°F (:[6°C).
Temperature sensing element touching cold coil, located behind air filter. Straighten away from coil.
Reset to a lower temperature.
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to
restart when set in the COOL mode.
Air conditioner
cooling_ but room
is too warm
- ice forming
on cooling coil behind
decorative
front
Outdoor
temperature
below
60 °F (16 °C). To defrost
the
coil, set
FAN ONLY mode.
Air filter may be dirty. Clean filten Refer to Care and Cleaning section. To defrost, set to FAN ONLY
mode.
Temperature is set too tow for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,
set temperature to a higher setting.
Air conditioner
coeling_ but room
is too warm
- NO ice forming
on
cooling coil behind
decorative
front.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too high. Set temperature to a lower setting.
Air directional louvers positioned improperly.
Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove "stored heat" from walls, ceiling,
floor and furniture.
Air conditioner
turns
on and off
rapidly,
Dirty
air filter
- air restricted.
Clean
air filter.
Outside
temperature
extremely
hot.
Set FAN speed
to a faster
setting
to bring
air through
cooling
coils
more
frequently.
Noise when unit is cooling.
Air movement
sound.
This
is norm&
If too
loud,
set to lower
FAN setting.
Window
vibration
- poor
installation.
Refer
to installation
instructions
or check
with
installer.
Water
dripping
INSIDE
when
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to
unit is cooling,
installation instructions or check with installer.
Water
dripping
OUTS][DE when
Unit removing large quantity of moisture from humid room. This is normal during excessively humid
unit is cooling,
days.
Remote
Sensing
Deactivating
Prematurely
(some
models).
Remote
control
not
located
within
range.
Place remote
control
within
20 feet
& 120 ° radius
of the
front
of the
unit.
Remote
control
signal
obstructed.
Remove
obstruction.
Room
too cold,
Set temperature too low. Increase set temperature.
Remote Sensing activated (on some models) and remote control located in Hot Spot - Relocate remote
control or deactivate remote sensing.
If These Solutions
Fail, Call 1=800=944-9044