Remove all packaging from inside the carton, along with any inserts placed into the side louvers.
Before you begin, thoroughly familiarize yourself with the control panel and remote as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the touch pad alone or with the remote.
Light Feature:
The display and all LED indicators on the control panel of the unit can be turned off by pressing the "Light" button on the remote control. If any other button of the control panel and remote control is pressed after that, the unit will beep to indicate it works as the corresponding direction of pressing specific button, and the display and LED indicators will illuminate accordingly, but they will turn off again in 5 seconds if no further operation.
Press the "Light" button again or unplug the unit to cancel this setting.
Battery Size: AAA
Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries. Caution for ingestion. Keep out of the reach of children.
NOTE
The following instructions represent the touch pad. The same instructions can be used for the remote control.
NOTE: The unit will run in Cool mode with Eco feature and Auto fan speed setting when used for the first time. With the Eco feature, when the room temperature is below the set temperature, the fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on. Eco feature can be activated or deactivated by pressing Eco button, but it is invalid in fan only mode.
Note: This mode is a fixed combination of Cool mode and Auto fan speed setting. In this mode, the fan speed can not be selected manually.
Note: In this mode, the fan remains on all the time with the compressor cycling on and off when room temperature is reached.
Note: Tap or hold either up () or down () button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62°F (17°C) and 86°F (30°C). If you want the display to read the actual room temperature. See "To Operate on Fan Only" section.
Note: The fan speed can be selected among four settings: Auto, Lo(Low), Med(Medium) and Hi(High), unless the unit runs in "Auto" or "Dry" mode, or the Sleep feature is activated.
Note: Fan starts at Low Speed and adjusts to a proper speed according to the room temperature dictates. For example, if the room doesn't get too warm, it will stay at the slowest speed. If the room temperature rises quickly, such as a door being opened, it will automatically go to the highest speed. The fan speeds will re-adjust back to the slowest speed as the room returns to the original set temperature.
Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air on some models. (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.
Note: In this mode, the air conditioner will work like a dehumidifier, but it will cool the room down meanwhile. The temperature can be adjusted between 62°F (17°C) and 86°F (30°C) and fan speed will be held at "Lo".
Note: In this mode, the unit will select Auto fan speed automatically, and the selected temperature will increase by 2°F 30 minutes after the mode is selected. The temperature will then increase by another 2°F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the "Sleep" mode and the unit will continue to operate as originally programmed. The "Sleep" mode program can be cancelled at any time during operation by again pressing the "Sleep", "Fan speed" or "Mode" button.
YOU WILL SEE:
Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Filter Reset" button and the light will go off.
To delay stop(or start), press the Timer button when the unit is power-on(or power-off), then the "timer off" indicator (or "timer on" indicator) will illuminate. Then adjust timer setting, tap or hold the UP arrow () or the DOWN arrow () to change delay timer at 0.5 hour increments, up to 10 hours, then at 1 hour increments up to 24 hours. The setting will be confirmed automatically in 5 seconds, then the control will count down the time (8, 7.5, 7, etc.) left, and all other settings will remain the same as they were before the timer setting is confirmed, until stop (or start).
Setting combination of "delay stop delay start" or "delay start delay stop" turn on is workable. Both "timer off" indicator and "timer on" indicator will illuminate then. The timer setting can be canceled by either pressing and holding the timer button for 2 seconds, or pressing the power on/off button at any time to turn off the unit directly.
This feature can be activated from the remote control ONLY, the unit must be in a cooling mode. To activate the remote sensing feature, point the remote control towards the unit and press the Remote Sensing button. Next, use the " " buttons to set the desired temperature at the remote. (Note that the set temperature will only be displayed on the unit itself ). The LIGHT on the unit control will illuminate to indicate it receives the signal. The LIGHT on the remote control will pulse each time it sends a signal. lt will periodically send this signal until the feature is deactivated by pressing the remote sensing button again. lf the unit does not receive the remote sensing signal during any 7 minute interval, the Remote Sensing feature will halt until the unit receives signal from the remote control again. The display on the remote control indicates the temperature at the remote ONLY.
NOTE: Unit display shows the set temperature. Remote display is actual temperature.
The Remote Sensing function can be terminated either by pressing the Remote Sensing button again or the main ON/OFF button on the unit.
Note: The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius.
If the display reads "AS", a sensor has failed. Contact your Authorized Frigidaire Service Center.
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
NOTE
The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time.
The Fresh Air Vent allows the air conditioner to:
Air directional louvers control air flow direction. Your air conditioner has the louver type described below.
The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed. Drag the adjuster tablet until the desired Left/Right direction is obtained. Pivot horizontal louvers until the desired Up/Down direction is obtained.
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards.
The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.
NOTE: When replacing the air filter after cleaning, make sure the tabs on the air filter are on the upper part of filter, and placed outward as shown in the drawing.
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of defective workmanship or materials in this appliance.
OCCURRENCE | SOLUTION |
Air conditioner will not operate. |
|
Air from unit does not feel cold enough. |
|
Air conditioner cooling, but room is too warm - ice forming on cooling coil behind decorative front |
|
Air conditioner cooling, but room is too warm - NO ice forming on cooling coil behind decorative front. |
|
Air conditioner turns on and off rapidly. |
|
Noise when unit is cooling. |
|
Water dripping INSIDE when unit is cooling. |
|
Water dripping OUTSIDE when unit is cooling. |
|
Remote Sensing Deactivating Prematurely (some models). |
|
Room too cold. |
|
If These Solutions Fail, Call 1-800-944-9044 (US) / 1-800-265-8352 (Canada) For Frigidaire Service.
Frigidaire.com USA 1-800-944-9044 Frigidaire.ca Canada 1-800-265-8352
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Frigidaire FFRE053WAE - 5,000 BTU Window-Mounted Room Air Conditioner Manual
Advertisement
Need help?
Do you have a question about the FFRE053WAE and is the answer not in the manual?
Questions and answers