3a
Hang the AirCom Zentral cabinet onto the wall-
mounting strip in such a way that the upper
edge of the appliance rear panel lies behind the
upper edge of the wall-mounting strip.
Align the cabinet approximately in the middle of
the wall-mounting strip, push it against the wall
and fix it to the strip at the top left and right by
means of both self-tapping, large-headed
screws.
The oblong holes in the appliance rear panel al-
low a sideways adjustment of the appliance
against the wall-mounting strip of approximately
5mm. Tolerances can thus be compensated.
The sealing strips on the rear panel must sit
flush on the wall-mounting strip.
If the heating pipework comes from the side,
remove the plastic cap at the bottom of the right
hand side panel so that the return pipe can be
fitted later.
3b
If the heating-ventilation system is to be fitted to
heater pipework coming from the wall on the left
side of the appliance (for instance in existing
buildings), OLSBERG offers suitable connect-
ing pipe sets as an accessory.
This pipework set makes the connection at the
rear of the appliance to the connections on the
right hand side of the appliance.
The installation of the pipework set to the rear
panel of the appliance takes place before the
heating-ventilation system is fixed to the wall-
mounting strip.
Installation sequence of pipework set:
Note: The connection to the heating system
A
Attention: Any side cladding elements (B) left
B
Fix the supplied plastic coated steel-spring
clips with screws 2.9x6.5 into the pre-
punched holes in the top and bottom of the
rear panel.
Insert the pipework set into the steel-spring
clips (pipework with corner valve for flow
points upwards, pipework with corner valve
for return points downwards).
takes place only after the radiator has
been installed in the appliance.
and right that may be present and
the cover (A) on the radiator must
be removed before installation in
the AirCom Zentral.
This is the only way that the nec-
essary flow of incoming air through
the radiator can be ensured, and
this is the only way that the
AirCom Zentral can work correctly.
33