Lang 236CM Installation Operation & Maintenance

Gas infrared cheesemelter

Advertisement

Quick Links

Installation, Operation, & Maintenance
Model: 236CM, 248CM,
Gas Infrared Cheesemelter
Lang Manufacturing
10 Sunnen Drive,
St. Louis, MO 63143
Part # 2M-60803-02
Phone:314-678-6315 Fax: 314-781-2714
Rev. C
www.langworld.com
July 22, 2008

Advertisement

Table of Contents
loading

Summary of Contents for Lang 236CM

  • Page 1 Installation, Operation, & Maintenance Model: 236CM, 248CM, Gas Infrared Cheesemelter Lang Manufacturing 10 Sunnen Drive, St. Louis, MO 63143 Part # 2M-60803-02 Phone:314-678-6315 Fax: 314-781-2714 Rev. C www.langworld.com July 22, 2008...
  • Page 2: If You Smell Gas

    3. If odor continues immediately call your dealer / installer or your fire department. Model No: Purchased From: Serial No: Location: Date Purchased: Date Installed: Purchased Order No: For Service Call: Lang Manufacturing 10 Sunnen Drive, St. Louis, MO 63143 Part # 2M-60803-02 Phone:314-678-6315 Fax: 314-781-2714 Rev. C www.langworld.com July 22, 2008...
  • Page 3: Table Of Contents

    THE INFORMATION IN THIS MANUAL IS CRUCIAL AND MUST BE RETAINED FOR FUTURE REFERENCE. READ, UNDERSTAND AND FOLLOW THE INSTRUCTIONS AND WARNINGS CONTAINED IN THIS MANUAL. TABLE OF CONTENTS CHAPTER PAGE TABLE OF CONTENTS ..................3 READ FIRST ......................4 SAFETY PROCEDURES ..................
  • Page 4: Read First

    IMPORTANT READ FIRST IMPORTANT THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER CAUTION SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
  • Page 5 IMPORTANT READ FIRST IMPORTANT Service on this, or any other, LANG appliance must be performed by NOTICE qualified personnel only. Consult your LANG authorized service agent directory or call the factory at 314-678-6315 or www.langworld.com For the LANG service agent nearest you.
  • Page 6: Safety Procedures

    Safety Considerations Your Lang Melter is manufactured to rigid standards. This equipment is N.S.F and ETL listed and meets safety and sanitation standards. The presence of safety equipment control and interlocks on an appliance and attendant components of installation cannot in and of themselves, assure absolute safety of operation.
  • Page 7: Equipment Description

    EQUIPMENT DESCRIPTION Lang Model: 236CM, 248CM Gas Infrared Cheesemelter Exterior The unit dimensions are 28” (71cm) High without legs, 21” (53cm) Deep, and 36”, 48” (91cm, 122cm,) Wide dependent on the actual model number. The Sides, Bottom, and Rear wall are of constructed stainless steel.
  • Page 8: Unpacking

    UNPACKING THE UNIT IS EXTREMELY HEAVY. FOR SAFE HANDLING, INSTALLER CAUTION SHOULD OBTAIN HELP AS NEEDED, OR EMPLOY APPROPRIATE MATERIALS HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY, OR PALLET JACK) TO REMOVE THE UNIT FROM THE SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
  • Page 9: Installation

    INSTALLATION THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED. DANGER FAILURE TO GROUND THE APPLIANCE COULD RESULT IN ELECTROCUTION AND DEATH. WARNING INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT.
  • Page 10: Gas Connection

    INSTALLATION CONT’D GAS CONNECTION This appliance must be installed under a ventilation hood. The installation of any components such as vent hoods, grease extractors, fire and smoke detection devices, or fire extinguisher systems, must conform to N.F.P.A Standard #96, latest edition.
  • Page 11: Initial Start Up

    INITIAL START UP During the first few hours of operation you may notice a small amount of NOTICE smoke coming from the unit, and a faint odor from the smoke. This is normal for a new unit and will disappear after the first few hours of use. PRE-POWER ON After the melter is connected to power and gas, prior to turning on, verify the following:...
  • Page 12: Operation

    DANGER OF SLIPS OR FALLS. GENERAL The Lang gas melter can be used to poach, sauté and brown. In addition to melting cheese on sandwiches, French onion soup, hot apple pie and casseroles, it may be used for finishing Italian, Mexican and au gratin dishes utilizing less energy than conventional broilers.
  • Page 13 OPERATION Cont’d OPERATING DO’S AND DON’TS Insure all dishes placed in the melter are oven safe. Pre-heat pans in the melter or on a stove. Turn products halfway through cooking, as needed. Use the unit in Automatic as much as possible, use Constant during peak periods. DON’TS Do not use the melter as a cooking or baking device;...
  • Page 14: Maintenance & Cleaning

    MAINTENANCE & CLEANING KEEP WATER AND SOLUTIONS OUT OF CONTROLS. NEVER SPRAY OR WARNING HOSE CONTROL CONSOLE, ELECTRICAL CONNECTIONS, ETC. MOST CLEANERS ARE HARMFUL TO THE SKIN, EYES, MUCOUS CAUTION MEMBRANES AND CLOTHING. PRECAUTIONS SHOULD BE TAKEN TO WEAR RUBBER GLOVES, GOGGLES OR FACE SHIELD AND PROTECTIVE CLOTHING.
  • Page 15 MAINTENANCE & CLEANING Cont’d PILOT BURNER ADJUSTMENT Pilot flame adjustment is accomplished at the brass tube fitting on the main manifold. The brass fitting located between the regulator and the solenoid valve which has the 1/8 inch tube connected to it is the adjuster. Turn the hex head screw clockwise to shorten the pilot flame, and counterclockwise to lengthen the pilot flame.
  • Page 16: Troubleshooting

    • No gas to unit • Defective tile assembly Service on this, or any other, LANG appliance must be performed by NOTICE qualified personnel only. Consult your authorized service station directory or call the factory at 314-678-6315, or www.langworld.com For the service agent nearest you.
  • Page 17 TROUBLESHOOTING Cont’d TEST Possible Cause Test • Reset Circuit breaker and re-test Tripped Circuit Breaker Defective Power Switch, Constant / Auto • Check switch for normal operation switch • Check Power cord for continuity* Defective Power Cord • Check unit for proper Water Column* Defective Regulator •...
  • Page 18: Parts List

    PARTS LIST July 22, 2008, Rev. C GAS CHEESE MELETER: 236CM & 248CM DESCRIPTION PART NO. Switch Toggle On-Off 2E-30303-06 Pilot Light 208/240V 6” Lead Black Body 2J-31601-01 Rack, 2ft 2B-50200-13 Rack, 3ft 2B-50200-14 Rack, 4ft 2B-50200-15 Rack, 5ft 2B-50200-29...
  • Page 20 STAR INTERNATIONAL HOLDINGS INC. COMPANY Star - Holman - Lang - Wells - Bloomfield - Toastmaster 10 Sunnen Drive, St. Louis, MO 63143 U.S.A. (314) 678-6303 www.star-mfg.com...

This manual is also suitable for:

248cm

Table of Contents