Contents 1. Contents of E920 Box. 2. E920 Assembly Instructions. 3. E920 Control Arm. 4. E920 Slider Arm Kit. 5. Tank Filling and Water Treat- ment. 6. Long Term Water Treatment CAUTION and Basic Operation. As with any piece of fitness equipment, 7.
Page 3
Box Contents E920 1x Main Frame with Telescoping Tube and Internal Gas Assist Shock 1x Seat and Base 1x Fill Funnel and Hose 2x Mainframe Bolts 3x Frame levelers 4x Spring Washers M10x 25 Hex Key 4x Frame Bolt M3x130x25...
E920 Assembly Instructions 4x 8x15mm Bolts and 4x M8 Spring Washers 3x Foot Leveler Adjuster Knob Step 1: Remove contents from box. Attach telescoping tube to the underside of the control arm using 4x M8x15mm bolts and 4x M8 spring washers.
Page 5
E920 Assembly instructions Step 2: Attach base plate to lower mainframe using 2x M10x25mm bolts, 2x M10 Nylock nuts and 4x 21x11x2 washers. M10x25mm Bolt M10 Nylock Nut 21x11x2 Washer Step 3: Tilt the seat rearward until transport wheel is engaged. Secure the seat in...
Use this feature to realign the rear with the front sprocket if needed or when changing to a new chain. E920 Slider Arms: Refer to following assembly page.
E920 Slider Arm Kit Installation Instructions Slider Arm Kit includes 1x Slider Arm Assembly Right (includes right handle), 1x Slider Arm Assembly Left (includes left handle), 2x Yellow Adjustment Knobs with Nylon Spac- ers and 1x 3mm Allen key. Note: Slider Arms are marked ‘L’...
Page 8
E920 Slider Arm Kit Installation Instructions Step 3: Thread Adjustment Knob onto axle to secure the assembly. Step 1: Mount the left Slider Arm onto the axle using the yellow indicator hole to align the slider and axle. Step 2: Tighten the set screw onto the axle and into the yellow indicator hole using the 3mm Allen key.
Page 9
Using the E920 Slider Arm The E920 Slider Arm Kit offers the user an entire range of added resistance settings and the ability to perform additional upper body workouts. To adjust, simply loosen the Adjustment Knobs, move Slider Arm to desired length and secure. Very little tension is needed.
Tank Filling and Water Treatment Note: A large bucket is required for filling (Not included). In areas where tap water quality is known to be poor, FDF recommends the use of distilled water. Open the tank plug and insert hose into tank (rotating the im- peller slightly may be neces- sary to allow the hose to pass), move the tank adjuster...
For replacement tablets, contact your local First Degree Fitness distributor or visit www.firstdegreefitness.com for distributor locations. Water treatment schedules for the E920 will vary according to the fluid tanks expo- sure to sunlight but expect 8-12 months near a bright, sunlit window and 2-4 years for a darker location.
Page 12
Note: For complete operational Quick start provides instant workout infor- instructions, please refer to the mation. Just start training to activate. You computer manual, which is in- can choose to change UNITS displayed. cluded with your E920. UNITS displays WATTS, RPM, MPH,...
Open the inspection plate hours for correct ten- and check tension using a sion. screwdriver or other tool. Tighten as required and re- fer to “E920 Control Arm” page for instructions. E920 HandGrip Check weekly using The HandGrips should be Assembly.
(see erratic com- cover and check behind magnetic ring. puter display). Sensor head to ring gap should be no more than 2.5mm. The E920 computer Batteries installed Reinstall batteries in correct position and does not illuminate incorrectly or try again. If the LCD screen fails to illumi- after battery installa- need replacing.
Page 15
Tank Belt Adjustment Step 1: Remove large metal in- spection plate as shown above right. Step 2: Using a long tool, push out the rear end cap as pictured right. This will give you access to the tank tensioning bolt (shown bottom right).
Page 16
E920 Exploded Diagrams Refer to Tank Assembly 20850 Refer to Slider Refer to Computer Arms Assembly Assembly Complete (P.18) 10067 10040 10043 Refer to HandleGrip Assembly (P.18) Refer to Control 10170 Arm Assembly 23921 10072 33937 10066 10070 23144 33938...
Page 20
A010 Tank Assembly 10207- Tank Plug Yellow 10039 (O Ring 32x3.5-CR) Refer to Tank Back Assembly A006 Sensor Kit Refer to Tank Cover Assembly 70321-Tank Plug Black 10044 Tank Black Outer Cover Ring 10039 (O Ring 32x3.5-CR) 10046 (Large Tank Seal) 10062 Bolt M3x12 A053 Flywheel Assembly E720/820/920 18 x 10035...
Page 21
Description Tank Cover Assembly 10027 Adjuster Handle Shaft 10028 Stainless 0.8mm Backing Plate 10036 10030 Blue Adjuster PP Tank Ring 10030 10032 Adjuster O Ring 12x9x1.5 10033 Stainless Washer 10x4.2x1 10034 Nut M4 Stainless 10028 10035 Bolt M4 Stainless 10036 Screw M3x20mm for Blue Tank Ring 10059 Level Decal 20R...
Page 22
Metal Frame – 10 Year Limited Warranty First Degree Fitness will repair or replace the metal Main Frame of the E920 should it fail due to any defect in materials or workmanship within 10 years of the original purchase. Warranty does not apply to frame coating.