Siemens SXG 75 Service Manual page 45

Hide thumbs Also See for SXG 75:
Table of Contents

Advertisement

External Antenna
7
Call from MS
8
TX GSM Band 1
9
RX GSM Band 1
10
Handover to GSM Band 2
Including Handover
Check
11
TX GSM Band 2
12
RX GSM Band2
13
Call relaese from MS
Final Inspection:
The final inspection contains:
1) A 100% network test (location update, and set up call).
2) Refer to point 3.3.
3) A random sample checks of:
- Data reset (if required)
- Optical appearance
- complete function
4) Check if PIN-Code is activated (delete the PIN-Code if necessary).
Basis is the international standard of DIN ISO 2859.
Use Normal Sample Plan Level II and the Quality Border 0,4 for LSO.
Remark: All sample checks must be documented.
Technical Documentation
TD_Repair_L1-L3_SXG75_R1.1.pdf
• GSM900
• high TCH
• second highest PCL
• BS Power = -75 dBm
• middle BCCH
• high TCH
• second highest PCL
• BS Power = -75 dBm
• middle BCCH
• high TCH
• BS Power = -102 dBm
• 50 Frames
• middle BCCH
• high TCH
• second highest PCL
• BS Power = -75 dBm
• middle BCCH
• high TCH
• BS Power = -102 dBm
• 50 Frames
• middle BCCH
Company Confidential
2005©BenQ
• Keyboard check
• Frequency Error
• Phase Error RMS
• Phase Error Peak
• Average Power
• Power Time Template
• RX Level
• RX Qual
• BER Class Ib
• BER Class II
• BER Erased Frames
• Frequency Error
• Phase Error RMS
• Phase Error Peak
• Average Power
• Power Time Template
• RX Level
• RX Qual
• BER Class Ib
• BER Class II
• BER Erased Frames
Release 1.1
• individual
check
• GSM Spec.
• GSM Spec.
• GSM Spec.
• GSM Spec.
11/2005