Installation Instructions; Install Cooktop; Make Gas Connection - KitchenAid KCGS350ESS00 Installation Instructions Manual

30" (76.2 cm) and 36" (91.4 cm) gas built-in cooktop
Hide thumbs Also See for KCGS350ESS00:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
I_+'o_II C_'_,F _, _ s_ _' _
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
Decide on the final location for the cooktop. Avoid drilling into or
severing existing wiring during installation.
1. Determine whether your cabinet construction
provides
clearance for installing clamping brackets at cooktop base
ends. This is the recommended
location. Clamping brackets
can be installed on the front and back of cooktop base
bottom, if necessary.
....... =
........ =
4=
Attach brackets to cooktop base bottom with bracket
attachment
screws. Securely tighten screws.
_--C
A. Cooktop
B. Cooktop base
C. 2" (5.1 cm) bracket attachment
screw
D. Clamping bracket (extends far
enough beyond cooktop base to
allow installation of clamping screws)
E. Countertop
Mc£®
s Con ®c
ion
A. Attachment
screw holes for optional front and back location
B. Cooktop base bottom
C. Attachment
screw
D. Clamping bracket (end locations recommended)
2. Using 2 or more people, place cooktop right side up into the
cutout.
NOTE: Make sure that the front edge of the cooktop is
parallel to the front edge of the countertop.
If repositioning
is
needed, lift entire cooktop up from cutout to avoid scratching
the countertop.
3. Remove the attachment
screws for the selected bracket
locations from the bottom of the cooktop base.
A. Edge of cooktop base bottom
B. Clamping bracket
Explosion Hazard
Use a new CSA International
approved
gas supply
line.
instal a shut-off valve.
Securely
tighten
al gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical flexible
connection
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.