Explosion
Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut=off valve.
Securely
tighten
aii gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples
of a qualified
person include:
licensed
heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 -latest edition or CAN/CGA B149 -latest
edition.
IMPORTANT:
Leak testing of the cooktop must be conducted
according to the manufacturer's
instructions.
Type of Gas
Natural Gas:
This cooktop is design-certified
by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
•
This cooktop is factory set for use with Natural gas. If
converting to LP gas, see the "LP Gas Conversion"
instructions
provided in the package containing literature.
The model/serial rating plate located on the underside of the
cooktop base has information on the types of gas that can be
used. If the types of gas listed do not include the type of gas
available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See the Gas
Conversion instructions
provided in the package containing
literature.