Electrical Requirements - KitchenAid KSSC36FTS Installation Manual

Architect series overlay series
Hide thumbs Also See for KSSC36FTS:
Table of Contents

Advertisement

Available languages

Available languages

84"
( 213.4 cm)
to bottom of solid soffit
/
Dimension
77"
(196 cm)
A
Width
(see chart following)
6"
15.2 cm'
.__
24"
(60.96
cm) min.
Width A
Width A for
Dimension
B
(as shown
Overlay Models
(as shown
Model
above)
(as shown above)
above)
36
351/2" to 353/4"
353/4" to 36"
4" (10.2 cm)
(90.2 cm to
(90.8 cm to 91.4 cm)
90.8 cm)
42
411W' to 413/4 ''
413/4" to 42 ''
71/2"(19.1 cm)
(105.4 cm to
(105.4 cm to
106.1 cm)
106.7 cm)
48
471/2" to 473/4"
473/4" to 48"
131/2" (34.3 cm)
(120.7 cm to
(121.3 cm to
121.3 cm)
121.9 cm)
NOTE: Flooring under refrigerator must be at same level as the
room. Face of cabinetry must be plumb.
Electr
cal Requ
rements
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
Before you move your refrigerator into its final location, it is
important to make sure you have the proper electrical connection.
Recommended
Grounding
Method
A 115 volt, 60 Hz., AC only, 15- or 20-amp fused, grounded
electrical supply is required. It is recommended
that a separate
circuit serving only your refrigerator be provided. Use an outlet
that cannot be turned off by a switch. Do not use an
extension cord.
IMPORTANT: If this product is connected to a GFCI (Ground Fault
Circuit Interrupter) protected outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Food quality
and flavor may be affected. If nuisance tripping has occurred, and
if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or
removing a light bulb, remove the top grille and turn the master
power switch to OFF or disconnect power at the circuit breaker
box.
When you are finished, turn ON the master power switch or
reconnect power at the circuit breaker box. Then reset the control
to the desired setting.