2.
Attach
direct wire
cable to strain relief
Put direct
wire cable
through
the strain
relief. The strain relief
should
have a fight fit with the dryer cabinet
and be in a
horizontal
position.
Tighten
strain relief
screw against
the direct
wire cable.
If your wiring looks like this:
4-wire
direct
connection:
Go to "4-Wire
Direct
Connection"
on this page.
and neutral
wire
Remove center
terminal
block
screw (B). Remove neutral
ground
wire (E) from external
ground
conductor
screw (A).
neutral
wire
3-wire
direct
connection:
Go
"3-Wire
Direct
Connection"
to
on page
12.
4=wlre
Direct
Wire
Connectlon
IMPORTANT:
A 4-wire
connection
is required
for mobile
homes
and where local
codes do not permit
3-wire
connections.
Prepare
your
4-wire
cable for
direct connection
Connect
neutral
ground
wire (E) and place
hooked
end (hook facing
right) of neutral
wire (white or center
wire) (C) of direct
wire
cable
under center
screw of terminal
block
(B). Squeeze
hooked
ends together
and
tighten
screw.
Direct
wire cable
must have 5 ft. (1.52 m) of extra
length
so
dryer
may be moved
if needed.
Strip 5" (127 mm) of outer covering
from end of cable,
leaving
bare ground
wire at 5" (127 mm). Cut 1
I/2Ww
(38
mm)
from remaining
3 wires. Strip insulation back 1" (25 mm).
Shape ends of wires into hooks.
Connect
ground
wire (green
or bare) (F) of direct
wire cable
to external
ground
conductor
screw (A). Tighten
screw.