QUADRUPLE SYSTEM MULTI R.A. . MULTIZONE 80H
Whichever indoor units are installed, cooling and heating capacity
depends on how many and which indoor units are operating at that time.
ODEL :
RAM―80QH5
POSSIBLE
CO BINATIONS
CAPACITY RATING
TO OPERATE
1.8
2.5
3.5
5.0
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
2.5+5.0
3.5+3.5
3.5+5.0
5.0+5.0
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
3.5+3.5
Two units
Each unit is connected to each compressor.
...
Two units
Two units are connected to one compressor.
...
OOL / HEAT APA ITY SPE . FOR INDOOR UNITS
TO BE ABLE TO OPERATE SIMULTANEOUSLY
COOLING
(kW)(RANGE)
CONSU PTION
1.80
(1.00-2.50)
2.50
(1.00-2.80)
3.50
(1.00-4.00)
(360-1280)
5.00
(1.00-5.60)
(360-2100)
1.80+1.80
(1.50-4.10)
(640-1240)
1.80+2.50
(1.50-4.50)
(640-1450)
1.80+3.50
(1.50-5.80)
(640-1940)
1.70+4.90
(1.50-7.20)
(640-2190)
2.50+2.50
(1.50-5.60)
(640-1720)
2.50+3.50
(1.50-6.60)
(640-2190)
2.50+4.50
(1.50-7.60)
(640-2840)
3.50+3.50
(1.50-7.60)
(640-2840)
3.10+4.40
(1.50-8.00)
(640-2990)
4.00+4.00
(1.50-8.20)
(640-3040)
1.80+1.80
(1.50-4.00)
(640-1230)
1.70+2.30
(1.50-4.50)
(640-1400)
1.60+2.40
(1.50-5.50)
(640-1830)
1.50+4.10
(1.50-6.20)
(640-2050)
2.50+2.50
(1.50-5.50)
(640-1830)
2.30+3.30
(1.50-6.20)
(640-2050)
2.80+2.80
(640-2050)
(1.50-6.20)
OMBINATIONS
OUTDOOR UNIT
POWER
A PARE
( A)
(W)
230V
560
2.5
(360-750)
780
3.4
(360-980)
1160
5.1
1910
8.4
1120
4.9
1320
5.8
1760
7.7
1990
8.7
1560
6.9
1990
8.7
2580
11.3
2580
11.3
2720
11.9
2760
12.1
1120
4.9
1280
5.6
1660
7.3
1860
8.2
1660
7.3
1860
8.2
1860
8.2
- 14 -
HEATING
CAPACITY RATING
(kW)(RANGE)
CONSU PTION (A)
2.50
(1.10-3.20)
3.90
(1.10-4.70)
4.80
(1.10-5.80)
6.70
(1.10-7.60)
2.50+2.50
(1.50-5.50)
2.50+3.90
(1.50-7.00)
2.50+4.80
(1.50-8.40)
2.20+6.00
(1.50-9.00)
3.90+3.90
(1.50-8.60)
3.90+4.80
(1.50-9.60)
3.00+6.00
(1.50-9.90)
4.70+4.70
(1.50-10.30)
4.00+5.60
(1.50-10.60)
4.80+4.80
(1.50-10.60)
2.25+2.25
(1.50-5.20)
2.20+2.60
(1.50-5.50)
2.00+3.80
(1.50-6.40)
1.70+4.50
(1.50-6.80)
2.90+2.90
(1.50-6.40)
2.60+3.60
(1.50-6.80)
3.10+3.10
(1.50-6.80)
OUTDOOR UNIT
POWER
A PARE
( W)
230V
690
3.0
(320-970)
1100
4.8
(320-1280)
1380
6.1
(320-1750)
2070
9.1
(320-2170)
1380
6.1
(600-1520)
1770
7.8
(600-1950)
2150
9.4
(600-2380)
2850
12.5
(600-3150)
2160
9.5
(600-2390)
2690
11.8
(600-2960)
3200
14.1
(600-3520)
3200
14.1
(600-3520)
3300
14.5
(600-3630)
3300
14.5
(600-3630)
1280
5.6
(600-1480)
1360
6.0
(600-1600)
1580
6.9
(600-1740)
1930
8.5
(600-2120)
1580
6.9
(600-1740)
1930
8.5
(600-2120)
1930
8.5
(600-2120)

Hide quick links: