Download Print this page

KitchenAid KDRS505XSS04 Installation Instructions Manual page 3

30" (76.2 cm) double oven dual fuel ranges

Advertisement

Available languages

Available languages

In the State of Massachusetts,
the following installation instructions apply:
• Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by
the State of Massachusetts.
• If using a ball valve, it shall be a T-handle type.
• A flexible gas connector, when used, must not exceed 3 feet.
Tip Over Hazard
A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation instructions.
Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without
anti-tip bracket installed and engaged.
Failure to follow these instructions can result in death or serious burns to children and adults.
h
Anti-Tip
Ra_
'''Bracket
To verify the anti-tip bracket is installed and engaged:
• Slide range forward.
• Look for the anti-tip bracket securely attached to floor or wall.
• Slide range back so rear range foot is under anti-tip bracket.
• See installation instructions for details.
INSTALLATION REQUIREMENTS
G ,ca
Gather the required tools and parts before starting installation.
Read and follow the instructions
provided with any tools listed
here.
Tools needed
Tape measure
3/8"nut driver
Phillips screwdriver
Marker or pencil
T20 ®Torx®tscrewdriver
Pipe-joint compound
resistant to LP gas
Flat-blade screwdriver
1/8"flat-blade screwdriver
Noncorrosive leak-detection
solution
Level
For LP/Natural
Gas
Hand or electric drill
Conversions
Wrench or pliers
1/2"combination
wrench
Pipe wrench
9/32"(7.0 mm) nut driver
ls/le" combination
wrench
Masking tape
1/8"drill bit
Burner grates
Burner caps
Oven racks
2 - #12 x 18/8 '' screws (for mounting anti-tip bracket)
Anti-tip bracket (taped inside upper oven with literature
package)
Anti-tip bracket must be securely mounted to the back wall or
floor. Thickness of flooring may require longer screws to
anchor bracket to subfloor. Longer screws are available from
your local hardware store.
Parts needed
If using a power supply cord:
A UL listed power supply cord kit marked for use with ranges.
The cord should be rated at 250 volts minimum, 40 amps or
50 amps that is marked for use with nominal 13/8 '' (3.5 cm)
diameter connection opening and must end in ring terminals
or open-end spade terminals with upturned ends.
Parts supplied
Check that all parts are included.
3 - 10-32 hex nuts (attached to terminal block)
3 - Terminal lugs
LP/Natural Gas Conversion Kit (located on back of range near
lower side)
A UL listed strain relief.
Check local codes and consult gas supplier. Check existing
electrical supply and gas supply. See "Electrical Requirements"
and "Gas Supply Requirements" sections.
It is recommended
that all electrical connections
be made by a
licensed, qualified electrical installer.
I"®TORX and T20 are registered
trademarks
of Saturn Fasteners, Inc.

Advertisement