2.
Attach terminal lugs (located in the package containing
literature) to line 1 (black), bare (green) ground, and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of
the terminal lug and insert exposed wire end through bottom
of terminal lugs. Securely tighten setscrew to
XX Ibs-in. torque. See Bare Wire Torque Specifications
chart.
!
!
!
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
8 gauge copper
25 Ibs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
3. Use 3/8"nut driver to connect the bare (green) ground terminal
lug to the center terminal block post with one of the 10-32
hex nuts.
A
B
F
E
D
C
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link
screw
D. Bare (green) ground wire
E. Line 2 (red)
E Terminal lug
4. Connect line 1 (black) and line 2 (red) terminal lugs to the
outer terminal block posts with 10-32 hex nuts.
5. Securely tighten hex nuts.
6. Replace terminal block access cover.
Mc <®
s Conn®c
Explosion Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut-off
valve.
Securely
tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified
person include:
licensed heating personnel,
authorized
gas company personnel, and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Typical flexible connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a lS/le" combination
wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
........ A
.... D
H
A. Gas pressure regulator
B. Use pipe-joint
compound.
C. Adapter (must have V2"male
pipe thread)
D. Flexible connector
E. Manual gas shutoff valve
F _/2"or 3/4"gas pipe
G. Use pipe-joint
compound.
H. Adapter
4. Gas supply pipe must be located within clearance area as
shown in the "Cabinet Dimensions"
illustration in "Location
Requirements"
section.