If Auto Sense is On, the Auto button light will turn Off and go into
Sleep Mode when the vent hood is not in use. If the vent hood is
turned On by the consumer or by Auto Sense, the Auto button
light will turn On.
To set Auto Sense:
Press AUTO.
To Select Auto Sense Cooktop Type:
NOTE: The range hood is factory-set
for the gas cooktop
mode.
Press and hold AUTO for 5 seconds to switch between the
gas cooktop and electric cooktop modes.
The Auto button light will flash 5 times when the range hood
is changed to the electric cooktop mode. Auto Sense is now
set to work with electric cooktops and ranges.
The Auto button light will flash 3 times when the range hood
is changed to the gas cooktop mode. Auto Sense is now set
to work with gas cooktops and ranges.
Changing the cooktop type will change the temperature
limit
for Auto Sense to turn On. When the range hood senses a
high enough temperature,
the fan will start automatically.
When the temperature
drops below the set temperature
limit,
the fan will stop automatically. The Auto button light will turn
Off after the range hood enters Sleep Mode, but Auto Sense
is still active.
To Deactivate Auto Sense:
If the Auto button is lit, press AUTO once to deactivate Auto
Sense. The Auto button light will turn Off.
If Auto Sense is in Sleep Mode, press AUTO once to
deactivate Sleep Mode and turn the Auto button light On.
Press AUTO again to deactivate Auto Sense and turn Off the
Auto button light.
Auto Sense will automatically
turn off after 2 hours of no
activation of the Auto Sense system. To reset Auto Sense
press AUTO.
Manual Vent Functions
Fan Speeds
Low
Med
Hi
Boost
Press LOW to turn the fan on at Low speed.
Press MED to turn the fan on at Medium speed.
Press HI to turn the fan on at High speed.
Press BOOST to turn the fan on at the highest
speed. Boost will automatically
turn Off after
10 minutes and the fan will switch to High
speed.
Timer
The range hood can be set to automatically turn off after
15 minutes.
1. Press and hold the desired fan speed button for 2 seconds.
The fan will run on the chosen speed for 15 minutes, and the
fan speed button light will flash continuously.
After 15 minutes, the fan will turn Off automatically.
2. Press the desired fan speed button again while the fan timer
is running to cancel the fan timer.
NOTE: Changing the fan speed or turning Auto Sense On will
also cancel the 15-minute timer.
Light
The range hood has both task and ambient lighting.
To operate the lights:
1. Touch LIGHT once and the LED task lights will turn On.
2. Touch LIGHT again and the LED task lights will turn Off. The
ambient lights will turn On.
3. Touch LIGHT a third time and the ambient lights will turn Off.
NOTE: To turn both the task and ambient lights on at the same
time, touch and hold LIGHT for 2 seconds. Touch LIGHT again to
turn the task and ambient lights Off.
RANGE HOOD CARE
Cleaning
IMPORTANT: Clean the hood and grease filters frequently
according to the following instructions. Replace grease filters
before operating hood.
Exterior Surfaces:
To avoid damage to the exterior surface, do not use steel wool or
soap-filled scouring pads.
Always wipe dry to avoid water marks.
Cleaning Method:
Liquid detergent soap and water, or all-purpose
cleanser
Metal Grease Filter
1=
Open the stainless steel panel. Grasp panel at the front
corners and pull down to disengage the 2 catch pins from the
spring catches. The panel is attached at the rear and will
rotate down.
D
Wipe with damp soft cloth or nonabrasive sponge, then rinse
with clean water and wipe dry.
A
C
A. Metal filters
C. Catch pins (2)
B. Stainlesssteel panel
D. Spring catches (2)