INTRODUCTION
These instructions outline the details for Lamp and Filter replacement in the LW650 projector (Model
No. 121-002103-01). NOTICE: Use only a Christie approved Lamp and Filter Kit for your specific
projector model.
KITS REQUIRED
003-120483-01 (Replacement Lamp)
003-002722-01 (Replacement Air Filter)
INSTRUCTIONS
LAMP REPLACEMENT
When the projected image darkens or color reproduction becomes poor, the lamp needs to be replaced.
NOTE: If the projector is ceiling mounted, or if the lamp bulb has broken, the lamp unit should also be
replaced.
projector before servicing or cleaning.
opened. The inside of the projector can become very hot and may cause injury.
result in malfunctions, fire hazard, or other possible accidents.
NOTICES: 1) Switch the lamp OFF before opening the lamp cover. 2) For continued safety, replace
with a lamp assembly of the same type. 3) Do not drop the lamp assembly or touch a glass bulb! The
glass can shatter and may cause injury.
LW650 Lamp/Filter Replacement Instruction Sheet
020-000185-01 Rev. 1 (03-2009)
LW650 Lamp/Filter Replacement
Always power down and disconnect/disengage all power sources to the
Allow the projector to cool for at least 45 minutes before the lamp cover is
Do Not operate the projector while any of the lamps are removed. This may
Instruction Sheet
1 of 3

Advertisement

loading

Summary of Contents for Christie LW650

  • Page 1 LW650 Lamp/Filter Replacement Instruction Sheet INTRODUCTION These instructions outline the details for Lamp and Filter replacement in the LW650 projector (Model No. 121-002103-01). NOTICE: Use only a Christie approved Lamp and Filter Kit for your specific projector model. KITS REQUIRED...
  • Page 2 LAMP TIME was reset. Refer to the value for proper maintenance. 2) Do not Figure 2 Lamp Time Reset reset the LAMP TIME without replacing a lamp. 2 of 3 LW650 Lamp/Filter Replacement Instruction Sheet 020-000185-01 Rev. 1 (03-2009)
  • Page 3: Replacing The Filter Cartridge

    FILTER TIME was reset. Refer to the value for proper maintenance. 2) Do not reset the FILTER TIME without replacing a filter. Figure 4 Filter Time Reset LW650 Lamp/Filter Replacement Instruction Sheet 3 of 3 020-000185-01 Rev. 1 (03-2009)