Operating the heating system

Maximum CH (boiler) flow temperature dial
The maximum CH (boiler) flow temperature ( fig. 4, item 8) is used to
set the upper CH (boiler) flow temperature limit. The unit is °C.
DANGER: Damage to the installation with underfloor
heating: by the floor being overheated.
▶ Limit the maximum CH (boiler) flow temperature
using the "CH (boiler) flow temperature" dial
( fig. 4, item 8) to the permissible flow
temperature of the floor heating circuit (usually
maximum 40 °C).
Display
The heating system status and values can be read out from the display
( fig. 4, item 9). If a fault occurs the display will immediately show the
accompanying fault code. The fault code display will flash if a locking
fault is detected.
"DHW mode" LED
The "DHW mode" LED ( fig. 4, item 10) lights up when a DHW request
has occurred and it is extinguished when this DHW request is no longer
required.
DHW temperature dial
The DHW temperature dial ( fig. 4, item 11) is used to select the
required temperature of the hot water in the hot water cylinder. The unit
is °C. This is only active with certain Bosch controls.
8
Operating the heating system
8.1

Menu structure

You can navigate through the menu structure of the central boiler on the
BC10 using the "Reset" button, the "Chimney sweep" button, the
"Service button" ( fig. 6, items 1, 2 and 3) and the display ( fig. 6,
item 4) in accordance with the menus in tables 4, 5 and.
8.1.2

Manual Operation menu

In manual mode, the heating system can be operated independent of a room controller (e. g. RC35).
Re-start manual operation after switching on the heating system, so that the system is permanently in operation (especially if there is a
risk of freezing).
Manual operation menu
[\/2/4|
Step 1
Display value. Currently measured CH (boiler) flow temperature in °C. Also see section 10.1, page 8.
Step 2
Activate manual operation?
To activate manual operation: Press and hold the d button for more than 5 seconds.
Step 3
[\/2/4}
Step 4
Display code: Operating phase: As soon as a flashing dot is shown in the right-hand bottom corner of the
display, manual operation is active. This means that the boiler is permanently in heating mode.
The maximum CH (boiler) flow temperature as set on the maximum CH (boiler) flow temperature dial of
the BC10 basic controller (control panel) now applies. The "Heat request" LED lights up.
Table 5 Manual operation
6
4
1
Fig. 5
BC10 basic controller
8.1.1

Normal Operation menu

Information about the operating status of the boiler can be displayed via
this menu. The currently measured values of the CH (boiler) flow
temperature (permanent indication), the working pressure and the
operating codes are shown. Proceed as follows:
Normal operation menu
Step 1 [\/2/4| Display value. Currently measured
CH (boiler) flow temperature in °C.
Also see section 10.1, page 8.
Step 2 Continue in Normal operation menu?
Step 3 Press the e button.
Step 4 [p/1.6| Display value. Currently measured
system pressure in bar.
Also see section 10.1, page 8.
Step 5 Press the e button.
Step 6 [-/h/\| Random display code. In this case:
Operating phase: Boiler in heating
mode. Also see section 10.2,
page 8.
Step 7 Have at least 5 seconds passed without a
button being pressed and/or has the mains
voltage been interrupted ?
Step 8 Press the e button.
Table 4 Normal operation
2
3
6 720 619 373-18.1TD
Yes:  step 3
No:  step 1
Yes:  step 1
No:  step 8
 step 1
 step 3
Yes:
 step 1
No:
6720813172 (2015/04)