The vent pipe should be located to prevent the
ingress of moisture and in a location where it will not
get blocked with leaves or any other debris. As wind
effects can create suction and pressure zones of
opposite sides of the dwelling it is recommended to
run the air vent from opposite poles (North, South,
East & West) of the dwelling and tee off for the air
supply to the stove. This should negate the effect
of suction and pressure zones. See Fig.4
Fig.4

CO ALARM

Waterford Stanley recommend the fitting of a CO
Alarm in the same room as the appliance, this is a
requirement under UK Building Regulations.
Further guidance on the installation of a carbon
monoxide alarm is available in BS EN 50292:2002
and from the alarm manufacturers instructions.
Provision of an alarm must not be considered a
substitute for either installing the appliance
correctly or ensuring regular servicing and
maintenance of the appliance and chimney
system.
WARNING:-
If the CO Alarm sounds unexpectedly:-
1. Open Doors and windows to ventilate the
room and then leave the premises.
2. Let the fire go out.

LOCATION

There are several conditions to be considered in
selecting a location for your Stanley Stove.
a. Position in the area to be heated, central
locations are usually best.
b. Allowances for proper clearances to
combustibles.

INSTALLATION CLEARANCES

Maintain at least the following clearances to all
combustible material:
From the front
From the back
From the sides
From the flue pipe
Brick wall minimum clearance, but allow access for
controls and water fittings.

FLOOR PROTECTION

It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.
It is recommended that a minimum clearance of
150mm be maintained from the sides and rear of the
appliance to a tiled fireplace or masonry wall, as
access is required for the controls. See Fig.5.
7
Note: When Installing
outside air pipe adhere
to 'Clearance to
Combustible' Section.
1
800 mm (31
")
/2
1
800 mm (31
")
/2
1
650 mm (25
")
/2
760 mm (30")
straight up only