SYSTEM INSTALLATION AND ELECTRICAL REQUIREMENTS

Electrical Code

Note: To the display system installer: This reminder is provided to call attention to Article 820-44 of
the National Electric Code that provides guidelines for proper grounding and, in particular, specifi es
that the cable ground shall be connected to the grounding system of the facility. Outlet shall be
installed near the equipment and shall be easily accessible.
NEC National Electric Code
Ground clamps
Note: Installation shall incorporate UL Listed external surge protection rated 2500 Vpk or less, for 150
to 300 Vac mains, installed in accordance with Article 285 of ANSI/NFPA 70 or applicable local codes.

Power Source

The product must be connected to a main socket outlet with a protective earthing connection.
The main plug is used as the disconnect device and shall remain readily accessible.
This product operates on 100-240 volts 60 Hz, AC current. Insert the power cord into a 120 volts 60
Hz outlet. Never connect the product to direct current or anything other than the specifi ed voltage.
To prevent electric shock from the product, do not use with an extension cord, receptacle, or other
outlet unless the blades and ground terminal can be fully inserted to prevent blade exposure.
CAUTION: Double pole/neutral fusing (ISO 3869. No 5036)
Ground clamp
Electric service
equipment
Antenna lead-in wire
Antenna discharge unit
(NEC Section 810-20)
Grounding conductors
(NEC Section 810-21)
Power service grounding
electrode system
(NEC Art 250 Part H)