Installation to Wood Stud Wall
• DO NOT lift more weight than you can handle. Always use an assistant or mechanical lifting equipment to safely lift
and position enclosure assembly (A).
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all
attached hardware and components.
• Tighten wood screws so that the enclosure assembly is fi rmly attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lbs. (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud fi nder
is highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs.
Installers are responsible to provide hardware for other types of mounting situations.
NOTE: This step is for mounting enclosure assembly (A) fl ush against supporting surface. For use with
3
mount, follow instructions provided with wall mount.
Use a stud fi nder to locate the edges of the studs and draw a vertical line down each stud's center. Place
enclosure assembly (A) on wall as a template,
that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia. holes 2.5" (64 mm) deep. Make
sure that the
enclosure
fi gure 3.1.
NOTE: If cord cover plate assembly (K) is used on the rear of the enclosure, you may use the 1/2" spacer (M)
between enclosure assembly and wall surface.
C
WARNING
level and mark the center of the six mounting holes. Make sure
is level and secure it using six 2.5" wood screws (C) and six washers (E) as shown in
A
E
fi g. 3.1