5.
Remove the wire harness from the control timer.
6.
Remove the single ¼-in. hex-head screw.
Wire Harness
7.
Lift up slightly on the tab where the screw
was located and rotate the timer clockwise (as
viewed from back) to release it from the 2 tab-
locks.
Control Timer Removed From Control Panel
Tab-lock
Tab-lock
– 15 –
Water Level Switch
•
The minimum fi ll volume is 9 gallons. The water
level measures approximately 7½ inches (6
holes) above the bottom of the basket.
•
The maximum fi ll volume is 22 gallons. The
water level measures approximately 15 inches
above the bottom of the basket (between holes
2 and 3 from the top).
Minimum Fill Level
To remove the water level switch:
1.
Disconnect power.
2.
Remove the water level switch knob by gently
pulling it outward.
3.
Place the control panel in the service position.
(See
.)
Control Panel