• Bolt gather to unit; Operating and Maintenance Instructions - For wood burning Jetmaster ..19 - 20 • Insulate entire unit and gather where painted red; • Bolt Lintel (optional) to unit - insulate between unit and Lintel;...
Summary of Minimum Jetmaster Installation Specs Summary of Minimum Jetmaster Installation Specs 1. HEARTH 2. FLUE Must be constructed from a non combustible material such as concrete, brick, or autoclaved • Single skin flue (stainless steel) must be enclosed with single skin brickwork, aerated lightweight concrete block.
Any cracks or cavities in the recess must be repaired and sealed. materials & any other Step 4. Tape the insulation to the back and sides of the Jetmaster, and slide it into combustible place. materials Note 1. Do not recess unit by more than 110mm.
Construction Specifications - Jetmaster Traditional Edwardian On Stud Wall Construction Specifications - Jetmaster Free Standing Metal Casing “A” Typical installation with exposed “flue” and or one length heat shield, refer to decro mesh diagram for firebox and flue clearances to combustibles.
• After installing the appliance, check that the chimney/flue system draws well. 430mm • Jetmaster recommends that all gas fires be serviced every 2 years. • All gas units must be fitted by a licensed gas fitter. • It is the responsibility of the gas fitter to follow the regulations set out in the Gas Code that dictate the procedures to follow when installing a gas appliance, particularly regarding gas pipe sizing and checking of pressures.
OPEN GAS FIREPLACE - Minimum Flue Height OPEN GAS JETMASTER Flue Termination HOW TO SET GAS PRESSURES 1 metre min. The Flue Terminal shall be located so that wind from any direction is not PRESSURE ADJUSTMENT FOR CAMPFYRE LOG likely to create a downdraught in the...
CLEANING Existing Consumer Piping Systems 1. The Jetmaster Log Pan is designed to give greater heat and fuel efficiency. For the When an additional appliance is to be connected to an existing consumer piping duration of the cold season the Log Pan should never be emptied. The resulting...
1. Use lugs and bolts provided and attach to flange on firebox. General Maintenance The visible parts of your Jetmaster can be cleaned with a damp cloth or soft brush. Should you wish you could repaint the unit with a heat resistant paint.