Jetmaster Standard 16 Installation And Operating Instructions Manual

Wood and coal convector fire
Table of Contents

Advertisement

WOOD AND COAL CONVECTOR FIRE
Installation and Operating Instructions
Please leave these instructions with the customer
December 2008

Advertisement

Table of Contents
loading

Summary of Contents for Jetmaster Standard 16

  • Page 1 WOOD AND COAL CONVECTOR FIRE Installation and Operating Instructions Please leave these instructions with the customer December 2008...
  • Page 2: Table Of Contents

    Bends ........................6 Flue Gathers ........................6 Installation Using an Existing Flue Gather ................ 6 Installation Using the Jetmaster Flue Gather and Adaptors ..........6 Hearths and Fire Surrounds ..................... 8 Protection of Heat and Shelves ..................8 Air Supply ......................... 9 Fitting the Firebox ........................
  • Page 3 Removal and Replacement of Throat Restrictors ............23 Cleaning and Maintenance ..................... 24 Jetmaster Guarantees ......................24 Jetmaster Provides Two Guarantees ................24 Two Year Guarantee (Registerable on Gas Fires) ............24 Ten Year Guarantee (Registerable) ................25 Terms and Conditions ..................... 25 Statutory Rights ......................
  • Page 4 DIMENSIONS STANDARD UNIVERSAL EXTRA MODEL 1050 FRAME WIDTH A mm 1150 HEIGHT B mm FIREBOX WIDTH C mm 1100 HEIGHT D mm DEPTH E mm OPENING REQUIRED WIDTH 1130 HEIGHT DEPTH WEIGHT OUTPUTS / EFFICIENCY / TEMPERATURES WOOD TRAY with WOOD ROOM SIZE HEATED M³...
  • Page 5 DIMENSIONS STANDARD UNIVERSAL EXTRA MODEL 1050 OUTPUTS / EFFICIENCY TEMPERATURES FRAME BASKET with SMOKELESS FUEL WIDTH A mm 1150 HEAT OUTPUT TO ROOM 10.1 SMOKELESS FUEL (Tested to BS3250) HEIGHT B mm TOTAL NOMINAL HEAT OUTPUT SMOKELESS FUEL WHEN TESTED TO EN13229: 2001 FIREBOX NET EFFICIENCY SMOKELESS FUEL...
  • Page 6: Installation Instructions

    Installation Instructions Introduction READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION. CLOSE ATTENTION TO THE DETAILS OF INSTALLATION WILL ENABLE YOU TO GET THE BEST RESULTS FROM YOUR FIRE. NOTE: THESE INSTRUCTIONS SHOULD BE RETAINED FOR FUTURE REFERENCE. There are three essential requirements for a successful installation. The fire must be correctly fitted into the recess and surround.
  • Page 7: Paint

    The flue must not be used for any other appliance or application. If a Jetmaster gas conversion kit is ever fitted in the firebox the damper or throat restrictor should be removed. If removal is not possible, it must be permanently secured in the open position.
  • Page 8: Chimneys

    These must be swept and inspected for dimensions and soundness before starting to install the fire. New Chimney Breasts Where a new chimney breast is to be built, the Jetmaster flue gather and adapter may be used in achieving connection to the flue. The components are available for Universal, Low and Extra Units Dimensions See the installation data table on pages 1 &...
  • Page 9: Bends

    Installation Using the Jetmaster Flue Gather and Adaptors The Jetmaster Flue Gather and adaptor is a convenient way of achieving the efficient transfer of smoke from the fire unit to the flue. It may be used bolted onto the firebox and the assembly slid under the flue as shown in the diagram below.
  • Page 10 FIRE Dim. F Dim. G Dim. H Dim. J Dim. K Dim.L FIRE Dim. F Dim. G Dim. H Dim. J Dim. K Dim.L Universal/Low 500 251.5 Universal/Low 500 391.5 Universal/Low 600 251.5 Universal/Low 600 391.5 Universal/Low 700 251.5 Universal/Low 700 391.5 Extra 700 263.5...
  • Page 11: Hearths And Fire Surrounds

    fire surrounds will require the fire to be set above hearth level, or forward of the chimney breast. The Jetmaster decorative contemporary frame requires sufficient clearance around the firebox to allow for the frame to fit flush with the fireplace surround. Take this into account when forming the recess and front finished face of the fireplace for the fire.
  • Page 12: Air Supply

    For shelves of a greater depth add 50mm (2”) to the shelf height for every 25mm (1”) increase in shelf depth. These are Jetmaster estimated distances, in certain cases further protection may be required to guard against heat on combustible materials, such as increasing the shelf height or shielding with a non combustible material.
  • Page 13: Fitting The Firebox

    If installing the fire in an existing fireplace, first remove all loose material from the recess and measure the opening and recess to ensure that the Jetmaster fire will fit. The opening must be high enough to allow the fire, and the flue gather if used, to be put into position, and must be sufficiently wide to permit the fire and its insulation to pass through.
  • Page 14: Fitting The Firebox Without A Jetmaster Gather

    Fitting The Firebox Without A Jetmaster Gather Place the fire in front of the prepared opening. Wrap the sides and back of the fire with the insulation and hold this in place with tape. Slide the fire into position in the prepared recess, taking care not to snag the insulation on the sides of the opening.
  • Page 15: Fitting The Firebox With A Jetmaster Gather

    Fitting The Firebox With A Jetmaster Gather The fitting of the firebox with the Jetmaster gather is similar to that when fitting with a concrete gather. However, the recess must be high enough to allow the fire, and the Jetmaster gather to be slid into position.
  • Page 16 An alternative use for the Jetmaster gather is to form a permanently fixed shuttering, supported by masonry piers. Gather support brackets may be made and fixed to the sloping sides of the gather at a height suitable for the piers. The cavity above the gather may be wrapped with flexible insulation or back filled with vermiculite cement.
  • Page 17: Fitting The Wood Tray And Log Retainer

    If fitting the Jetmaster contemporary decorative frame then sufficient clearance should be allowed around the outside of the fire for the frame to fit flat to the wall. The distance from the top of the hearth to the underside of the firebox should be 95mm minimum.
  • Page 18: The Arched Lintel

    flue if a gather is not used. It is possible to use both an arched lintel and a Jetmaster steel flue gather. Fillet Plate...
  • Page 19: Commissioning

    Do not use black leading or paint the interior of the firebox. Lighting after installation The Jetmaster should not be lit until all cement and plasterwork is completely dry and cured. When installation has involved building in cement mortar allow:- a.
  • Page 20: Handing Over

    Handing Over Read the Users instructions and instruct the user on the operation of the fire and cleaning methods. Leave instructions with the user. The user should be told that any odours are due to the newness of materials and should disperse after a few hours operation.
  • Page 21: Users Instructions

    This appliance is designed for intermittent operation and is intended for the purposes of room heating. It is designed to burn only the recommended fuels specified by Jetmaster and shall not be used with any liquid fuels or as an incinerator.
  • Page 22: Important

    DO NOT touch the external surfaces, air outlet or hood when the fire is alight as these surfaces become hot. DO NOT modify the appliance in any way. ONLY modifications authorised by Jetmaster may be carried out. Only genuine Jetmaster replacement parts shall be used.
  • Page 23: Operating Instructions

    Wood Burning Trays and Basket Grates Jetmaster fires may be used to burn a variety of fuels. Fuels must not be burned directly in the firebox. A range of wood burning trays, basket grates or gas burners are available to ensure that each fuel is burned in the most effective way.
  • Page 24: Lighting With Basket Grate

    MAXIMUM REFUEL WEIGHT MINIMUM REFUEL INTERVAL BASKET GRATE WOOD MAXIMUM REFUEL WEIGHT MINIMUM REFUEL INTERVAL Note:- Data was derived using the following fuels, WOOD:- Beech, Birch, Hornbeam. SMOKELESS FUEL:- Homefi re. In accordance with EN13229: 2001. E = Jetmaster Figures...
  • Page 25: Recommended Fuel Types

    Low models and some older versions of the wood and coal convector box are not suitable for gas conversions. If a Jetmaster gas conversion kit is ever fitted in the firebox the damper or throat restrictor should be removed. If removal is not possible, it must be permanently secured in the open position.
  • Page 26: Servicing Instructions

    Servicing Instructions IMPORTANT – ALLOW THE FIRE TO COOL BEFORE COMMENCING SERVICING OR CLEANING Servicing To ensure safe, efficient operation of the appliance, it is necessary to carry out routine servicing at regular intervals. The frequency of servicing will depend on the particular installation conditions and the frequency of use.
  • Page 27: Jetmaster Guarantees

    The full terms and conditions are set out below and/or over the page. Two Year Guarantee (Registerable on Gas Fires) Jetmaster Fires Ltd (“Jetmaster”) is so confident in the quality and design of its products that it provides a Two Year Guarantee automatically on all Wood and Coal Products against defects in materials and workmanship.
  • Page 28: Ten Year Guarantee (Registerable)

    Guarantee. Ten Year Guarantee Wood and Coal (Registerable) Jetmaster Fires Ltd (“Jetmaster”) is so confident in the quality and design of its fireplace units that it provides a Ten Year Guarantee against defects in materials and workmanship in its Standard, Universal, Low and Extra Fires (Firebox Only).
  • Page 29: Statutory Rights

    12. Jetmaster will not be responsible for any incident, indirect or consequential damages, except as provided by law. 13. Jetmaster neither assumes, nor authorises any third party to assume, on it’s behalf, any other liabilities with respect to the sale of this “Jetmaster” fire.