Offsets/Returns - Vermont Castings DSR42 Owner's Manual

Woodburning fireplace
Hide thumbs Also See for DSR42:
Table of Contents

Advertisement

B. Offsets/Returns
Use an offset/return to bypass overhead obstructions.
An offset and return can be used as a single entity or separated by chimney section(s).
WARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could cause
overheating and fire. Secure offsets with screws ( not to exceed 1/2" / 13 mm in length) Secure returns with strapping.
Straight chimney sections may be secured with screws. Keep chimney sections from separating or twisting.
Measure the shift needed to avoid the overhead obstruction. Refer to dimension A in Figure 4.2.
Find the appropriate A dimension listed in Table 4.3. The B dimension coinciding with the A dimension measurement in
Table 4.3 represents the required vertical clearance needed to complete the offset/return.
Read across the chart to find the number of chimney sections/model numbers needed between the offset and return.
Figure 4.2
Chimney Offset/Return
Table 4.3 Offset Dimensions
A
B
in.
mm
in.
4 7/8
124
17 7/8
7 1/4
184
22
9 3/4
248
26 1/8
10 1/4
260
27 1/4
12 3/4
324
31 3/8
13 1/4
337
32 3/8
15 3/4
400
36 5/8
18 1/8
460
40 3/4
18 3/4
476
41 3/4
21 3/4
552
47
22 1/4
565
48
24 3/4
629
52 1/8
27 3/4
705
57 3/8
28 1/4
718
58 3/8
30 3/4
781
62 1/2
33 3/4
857
67 3/4
36 3/4
933
73
39 3/4
1010
78 1/8
41 1/8
1045
82 3/8
45 3/4
1162
88 1/2
48 1/8
1222
92 3/4
51 3/4
1314
98 7/8
Proper assembly of air cooled chimney parts results in an overlap of chimney joints
of 1-1/4 in. (32 mm). Effective length is built into this table.
16
VCG Designer Series • DSR42 Installation Manual • 4012-134 • Rev A • 02/20/15
A
B
1-1/4 in. (32 mm)
OVERLAP
SL1106
SL1112
SL1118
mm
SL406
SL412
SL418
454
-
-
559
1
-
664
2
-
692
-
1
797
1
1
822
-
-
930
-
2
1035
1
2
1060
-
1
1194
-
-
1219
-
-
1324
1
-
1457
-
1
1483
-
-
1588
1
-
1721
-
1
1854
-
-
1984
-
-
2092
1
-
2248
-
-
2356
1
-
2511
-
-
Example:
Your "A" dimension from Figure 4.2 is 14 1/2 in.
(368 mm). Using Table 4.3 the dimension closest to, but
not less than 14 1/2 in. (368 mm) is 15 3/4 in. (400 mm)
using a 30° offset/return.
You determined from the table that you would need 36-
5/8 in. (930 mm) (Dimension "B") between the offset and
return.
The chimney component that best fits your application is
two SL1112s.
Note: SL400 series pipe available
SL1136
SL1148
for Canada ONLY.
SL436
SL448
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
-
-
-
-
-
-
-
-
1
-
-
2
-
-
-
1
-
-
1
-
-
1
-
-
-
1
-
-
1
-
-
1
1
-
1
-
2
-
-
2
-
-
1
1
-
1
1
-
-
2

Advertisement

Table of Contents
loading

Table of Contents