LE CACHE 1400 Owner's Manual page 21

Contemporary, loft and wine vault series european country series mission series
Hide thumbs Also See for 1400:
Table of Contents

Advertisement

L E C A C H E P R E M I U M W I N E C A B I N E T S
Protection
Mechanisms
Scenario
P2 > 70°F for more
than 1 hour
P3 > 125°F for more
than 2 hours
Optional Protection
Mechanisms
P3 > 125°F for more
than 2 hours
Protection Mechanisms
To protect the components in the cooling unit as well as
the wine inside the cellar, the cooling unit is programmed
to shut down certain components under certain
circumstances, as follows:
What it means
The evaporator probe
is measuring
temperatures that are
too warm
The condenser probe
is measuring
temperatures that are
too hot
CellarPro cooling systems can be programmed to turn off
the compressor and condenser fan in the event of an HA2
alarm, as described below. If you'd like to turn on this
protection mechanism, please call us toll-free at
877.726.8496
The condenser probe
is measuring
temperatures that are
too hot
What happens
The evaporator fan will turn off
until the evaporator temperature
falls below 70°F
The compressor and condenser
fan will turn off until the
condenser temperature falls
below 120°F
The compressor and condenser
fan will turn off until the condenser
temperature falls below 120°F
-20-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2400310038005200

Table of Contents