L E C A C H E P R E M I U M W I N E C A B I N E T S
CellarPro cooling systems can be programmed with advanced settings to achieve more
control over conditions inside the cellar.
Differential, and alarm settings all can be modified for custom applications. To access the
advanced settings, do the following:
• Press the "Set" button and the "Down" button together at the same time, and hold for
three seconds. Then, use the "Up" or "Down" button to scroll to the following screen:
Advanced Operation
HUMIDITY: The factory preset for this setting is "0".
If the humidity inside the cellar is too low, press the "Set"
button, then use the "Up" button until the desired setting
is reached. The recommended range for this setting is 0-
6.
TEMPERATURE DIFFERENTIAL: The factory preset for
this setting is "4".
This setting determines the Temperature Differential and
therefore the temperature at which the cooling unit will
cycle on. The recommended range for this setting is 4 or
5.
HIGH TEMPERATURE ALARM:
this setting is "70".
This setting designates the High temperature inside the
cellar at which the alarm is triggered. We recommend
leaving this setting at the factory preset.
LOW TEMPERATURE ALARM: The factory preset for this
setting is "45".
This setting designates the Low temperature inside the
cellar at which the alarm is triggered. We recommend
leaving this setting at the factory preset.
ENERGY SAVINGS MODE DIFFERENTIAL: The factory
preset for this setting is "4".
This setting increases or decreases the Temperature
Differential for the Energy Savings Mode.
recommended range for this setting is 2-4.
Conditions like humidity, the Temperature
The factory preset for
The