DIDO DI Enable
Description:
Set or show the system digital input0/1.
Syntax:
DIDO Di_en [first|second] [enable|disable] [hightolow|lowtohigh]
Parameters:
: Digital Input/Output 0
first
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
enable : Enable digital input0/1 function
disable : Disable digital input0/1 function
(default: Set or show digital input/output/fault alarm 0/1 status)
: Trigger -> high to low
hightolow
: Trigger -> low to high
lowtohigh
(default: Set or show digital input/output 0/1 trigger)
DIDO DO Act
Description:
Set or show the system digital output0/1 action.
Syntax:
DIDO Do_act [first|second] [port|power] [enable|disable]
Parameters:
: Digital Input/Output 0
first
second : Digital Input/Output 1
(default: Set or show digital input/output first(0)/second(1) select)
: port fail
port
: power fail
power
: DI1 trigger
DI1
: DI2 trigger
DI2
(default: Set or show digital output/fault alarm 0/1 action)
600