SW No.
SEITING ITEM
CONTENTS
SE'tTING NO.
FACT. SET
EXPLANATION
79
Interval between
75 msec.
00
00
This is to set the interval between RTC and Q,
RTC and Q
0.3 sec.
01
for the purposeof correctingthe mismatching
0.5 sec.
02
of between Sanyo and other manufacturers
machine.
CCITT recommendationis 75 f 20 ms.
81
FSK delay
O msec.
00
00
This is to set the delay for correcting the"
100 msec.
01
mismatching of between Sanyo and other
200 msec.
02
manufacturers machine.
300 msec.
03
400 msec.
04
82
Tx.
Attenuator
0to15db
ooto15
06
This is to set the transmission level attenuation
for control and video signals.
83
DTMF Attenuator
0to15db
Ooto 15
04
This is to set the transmission level attenuation
for Dual Tone Modulated Frequency (DTMF)
dial.
.—
84
Cable Equalizer
O km-
00
01
An equalizer which adjusts the characteristics
1.8 km
01
of the ,non-loaded cable between fax and
3.6 km
02
exchange station. Set in response to the
5.6 km
03
distance to the exchange.
88
Closed Reception
OFF
00
00
Even when the select reception is set recep-
Sanyo free mode
ON
01
tion is free from any Sanyo fax machines at
ON (SETTING
No.
01).
* In case of fixing the overseas transmission mode, set to SW No. 71 to 01, SW No. 78 and 79 to 01 or 02.
* The SW No. 60 through 88 are classified as follows.
60.61
: For testing purpose
66
: For checking the party's responce
67 through 74 : Countermeasure for the reception problem
75 through 81 : Countermeasure
for the transmission problem
82 through84 : Countermeasure
for the problem caused by line characteristics
88
: Others