Sanyo SFX-11 Service Manual page 38

Hide thumbs Also See for SFX-11:
Table of Contents

Advertisement

ii
——
_.-— —
W No.
S=ING
ITEM
'-----------
.7 .
.
. . . .
CONTENTS
SEITINC:NO.
FACT. SET
EXPfANATION
———.
——— .——
-69
TCF check interva;- V29
.-
V27
'-- ---------------1
Set the time from the recognition of the train-
5ms
l15ms
00
00
ing by the Modem to starting the training
60 ms 170 ms
01
check (TCF).
100ms
210ms
02
Set to correct the mismatching of between
Sanyo and other manufacturer's machine.
——
.
— —.—. — .. —. — ——
— -— —.- —...-———
—— - -
70
F;K check before
OFF
I 00
When this unit can not receive the high speed
phase C
ON
01
01
training signal by the echo of CFR (E-52), set to
off (SETTING
No. 00).
—---——
Allowance of
71
5%
00
'---
When
receiving
consecutive
error
lines
Error lines
6V0
01
exceeding the setting number, this unit moves
794
02
to the sequence of bad copy quality and send
8%
03
RTN to transmitter.
Wo
04
When the E-30 occurs frequently, set the
10-30?"0
05-25
05(1 0?!0)
number to higher value but printing quality is
getting worse.
_.—
72
Continuous
3 lines
00
Error line (STD)
4 lines
01
5 lines
02
6-23
lines
03-20
03
73
Continuous
6 lines
00
Error line
7 lines
01
8 lines
02
9-26
lines
03-20
06
—.
74
Carrier off
O sec.
00
This is to set the allowance of the carrier off
detection
0.5 sec.
01
duration.
1.0 sec.
02
If the carrier off duration is less than the setting
1.5 sec.
03
value, reception is continued.
2.0 sec.
04
2.5 sec.
05
3.0 sec.
06
06
3.5 sec.
07
4.0 sec.
08
4.5 sec.
09
5.0 sec.
10
5.5 sec.
11
6.0 sec.
12
-... .. ..—.. . — ..
. .
.-
..—-— .
———-. -— .-—. — -..——- —---- . -.———-—
—— .-——--- --———-— —.
75
Tx. start speed
2400 BPS
'" -
00
This is to set the training start speed of the
4800 BPS
01
MODEM.
7200 BPS
02
It is recommended that if Tx. error occurs
9600 BPS
03
03
frequently set to 4800BPS.
-.—....— ——.—. —-.—.—-
---—-----
76
TSI
'-"
Non
00
This is" to"set the condition of transmitting TSI.
Tx. Always
01
Tx. only when
02
01
CSI receives
——
77
DCS timing
1st DIS
00
00
This is to set the responce of DCS cor-
2nd DIS
01
responding to DIS.
In order to consider the influence of the echo
while transmitting to overseas fax. 2nd DIS
(SEITING No. 01) mightbe effective.
---- ..———
78
——.
———..
—.—
Intervalbetween
"
75 msec
00
00
This is to set the interval between DCS and
DCS and Training
0.3 sec.
01
training, for the purpose of correcting the
0.5 sec.
02
mismatching of between Sanyo and othel
manufacturers machine. CCllT recommenda-
tion is 75 *20
ms.
9C
—au—

Advertisement

Table of Contents
loading

Table of Contents