E50 - E59 Cut-off other pa~
CODE
CONTENTS
=
50
DCN reception or unknown
51
Triple trial of DCS, DTC or
NSS signal
52
T6 time over
53
Carrier drop during Phase C
54
Q, PRI-Q tripple trial
59
Multipage (mode change) T1 time
over
classi-
fication
T, R
T
R
R
T
t
SYMPTOM
and NOTES
r"
Check the communication status between the parties.
When STOP key is pressed by the transmitter, DCN signal
comes after PIX. (PIX picture signal)
Check the communication status between the parties.
If the other parly could not receive DCS signal, DIS signal
would be retransmitted. In other cases, it is possible that the
other patly disconnected the line by some reasons.
Although MCF signal to respond MPS or CFR signal was
transmitted, no carrier signal received within 6 seconds.
Cl EOP, MPS, EOP General terms
E60, E62 Incomplete transmisaiin due to deficient line.
'K-
CODE
CONTENTS
classi-
fication
SYMPTOM
and NOTES
60
Fall-down Out
T
Training failure even with fall-down to 2400 bps.
62
Continuous 300 BPS
T, R
This error may be caused by the line noise.
71
Unhatching of key code
R
Telephone number does not match when the select reception
is set
77
40 ms of 9600 BPS only
T
E80 - E85 DCS, NSS command error
CODE
CONTENTS
80
Other company's NSS
81
No R command
(receive command)
82
Original size A3
83
64 command for A4 machine
85
Minimum transmission time error
L
'classi-
fication
R
R
R
R
R
--
SYMPTOM
and NOTES
"L
—23—