Advertisement

E1O, E12 The other pafty does nol respond
CODE
CONTENTS
classi-
fication
SYMPTOM and NOTES
10
TI time over
T, R
Even 35*
5 seconds passed after starting communication, no
signal received from the party.
12
No responce on redial
T
No responce from the pafty even redialing of the timer
transmission is carried out
E20 - E27
Own machinetroubles
CODE
CONTENTS
classi-
fication
SYMPTOM
and NOTES
20
Stop
switch is ON
ALL
21
Original jam
T
23
No recording paper
R
26
No original for timer transmission
T
;.'
27
Timer operation is cancelled
TIMER
E30 - E33 Image deficiency
d
,
CODE
30
31
32
33
CONTENTS
Exceed the error line limitation
RTN transmission
RTN reception
classi-
fication
R
R
T
SYMPTOM and NOTES
These errors may be caused by the S/Nor
deflection on the
line.
Check the disturbance and verify the incoming signal level
using the level meter.
Test the setting of the appropriate equalizer to compensate the
line loss.
I
Over 5 seconds per line
R
E40, E41 Emor in the other party
CODE
CONTENTS
classi-
fication
SYMPTOM
and NOTES
40
No recording paper in the other
T
P@
41
No polling original in the other
P-R
P@
-