Operating Instructions; Glass Information; Louvre Removal; Window Frame Assembly Removal - Majestic fireplaces LDVR1 Installation Instructions And Homeowner's Manual

Builder rear vent direct vent
Table of Contents

Advertisement

Glass Information

Only glass approved by CFM Corporation
should be used on this fireplace.
The use of any non-approved replacement glass will
void all product warranties.
Care must be taken to avoid breakage of the glass.
Do not operate appliance with glass front
removed, cracked or broken.
Replacement glass (complete with frame
window) is available through your CFM
Corporation dealer and should only be installed
by a licensed qualified service person.
�������

Louvre Removal

The top louvre panel
is removed by lifting
the panel vertically and
pulling it away from the
appliance. (Fig. 39) The
lower access door is
hinged along the bottom
edge and is folded
down to allow access.

Window Frame Assembly Removal

1. Turn the fireplace OFF (including the pilot)
2. If the unit has been operating allow time for the
components to cool.
3. Remove the top louvre assembly.
4. Open the lower louvre panel.
5. Release the two clamps securing the lower edge of
the window frame assembly by pulling down on the
handles. (Fig. 40)
10007317

Operating Instructions

��� ����� ����
����� ������
�� ��� ����� �����
����� �������
����� ����� ��������
�� ����� ������
2.
Louvre
1.
Glass Panel
FP1227
Fig. 39 Remove top louvre
assembly.
FP1227
Louvre removal
11/02
LDVR Series Direct Vent Gas Fireplace
6. Tilt the window frame assembly out slightly at the
bottom, lift the window frame assembly up and away
from the fireplace.
7. To replace the window frame assembly reverse
the procedure.
Window
Frame
Assembly
Fig. 40 Window frame assembly removal.

Glass Cleaning

It is necessary to periodically clean glass. During start-
up condensation, which is normal, forms on the inside
FP1228
of the glass. This condensation causes lint, dust and
remove glass frame
other airborne particles to cling to glass surface.
11/02
Also initial paint curing may deposit a slight film on
the glass. It is therefore recommended the glass be
cleaned two or three times with a non-ammonia based
household cleaner and warm water (We recommend
gas fireplace glass cleaner) within the first few weeks of
operation.
After the initial cleaning process the glass should be
cleaned two or three times during each operating
season depending on the environment in the house.
Clean glass after first two weeks of
operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.
Lower Clamps
Window
Frame
Assembly
Pull Clamp
Hook
Push
Clamp
Handle
FP1228
23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

33ldvr36ldvr39ldvr43ldvr

Table of Contents