Majestic fireplaces LDVR1 Installation Instructions And Homeowner's Manual page 14

Builder rear vent direct vent
Table of Contents

Advertisement

LDVR Series Direct Vent Gas Fireplace
20"
(508mm)
Straight Venting
DVR584-600
20"
Rear vent no elbows
(508mm)
Max.
2/99 djt
45°
REAR VENT-TOP VIEW
Rear Vent Corner Installation
Fig. 14 Rear vent applications, one 45° elbow.
Rear Wall Installation
Twist Lock Pipe
STEP 1
Locate vent opening on the wall. To locate hole center
consult with appropriate fireplace dimensions, Page 4.
Frame as shown below.
NOTE: When using flex vent, the opening will have to
be measured according to the 1/2" (13 mm) rise in 12"
(305 mm) vertical run.
Combustible Walls (Fig. 15): Cut a 10³⁄₈"H x 9³⁄₈" W
(264 x 240 mm) hole through the exterior wall and
frame as shown.
Noncombustible Walls (Fig. 15): Hole opening must
be 7¹⁄₂" (190mm) in diameter.
STEP 2
Measure wall thickness and cut zero clearance sleeve
parts to proper length (MAXIMUM 12"/305 mm). As-
semble sleeve and attach to firestop with #8 sheet
metal screws (supplied). (Fig. 16)
14
Top View
20"
(508mm)
Max.
Top View
FP836
Rear Vent-Top View
11/21/98
Vent Opening for Combustible Wall
10³⁄₈"
(264mm)
Fireplace Hearth
Opening for Noncombustible Wall
Fig. 15 Locate vent opening on wall.
45°
Adjustable
Zero Clearance
Sleeve
#8 Screws
(2)
Adjustable Zero Clearance Sleeve
Fig. 16 Adjustable zero clearance sleeve.
STEP 3
Measure from the fireplace collar or elbow face to face
of outside wall (add 2" for vent pipe overlap). Mark
pipes and cut to length. It is very important that the two
pipes are flush with the outside wall once the fireplace
is in its final location. (Fig. 17)
STEP 4
Slip 4" and 7" pipes onto respective flue collars. Make
sure to fix to the fireplace collar the 4" pipe with three
(3) screws before fixing the 7" pipe on the 7" collar.
Both pipes must be on a level plane. (Fig 18)
STEP 5
Guide the vent termination 4" collar into the 4" pipe then
the 7" collar into the 7" pipe. Do not force the venting
into position. If the pipes do not line up with the termi-
nation collars, disassemble pipes and reattach to the
fireplace collar. (Fig. 18)
STEP 6
Secure fireplace to floor through floor holes and adjust-
able frame drywall strip (nailing flange) to frame. (Refer
to Framing & Finishing Section).
9³⁄₈"
(240mm)
Framing
Detail
7¹⁄₂"
(190mm)
#8 Screws (2)
VO584-100
Vent Opening
2/99 djt
Firestop
ZCS101
Zero Clearance Sleeve
3/11/99 djt
VO584-100
Max. Length
12" (305mm)
#8
Screws
(2)
ZCS101
10007317