Chapter 6: Engineering Mode; Engineering Mode - Matrix S5X-04 Service Manual

Table of Contents

Advertisement

6.1 USINg ENgINEERINg MoDE
To enter Engineering Mode, hold the LEVEL UP and DOWN keys for 3-5 seconds until Manager Mode appears on the middle LED display.
Press the LEVEL UP or DOWN key to scroll to Engineering Mode. Press ENTER to go into Engineering Mode.
CoDE
Disable Errors
Speed Units
Machine Type
Power Save Time
Pause Time
Serial Number
Club ID
Adjust Resistance
ErP Mode (Sleep
Time)
Audio Source
Volume Control
AM System
12

CHAPTER 6: ENgINEERINg MoDE

DEfAUlT
oPTIoNS
No
Yes or No
Mile
Mile or Kilometer
S5x
S5x
30 Seconds
30-60 Seconds
30 Seconds
15 - 120 Seconds
N/A
N/A
N/A
N/A
-5
-10 ~ 10
Off
Off or On (1-30
Minutes)
Off
Off / TV / PC TV /
Remote TV
TV/ PCTV:
1~ 32
Output:13
REMOTE TV
1~ 32
Output:13
REMOTE TV
1~ 15
Input:15
RF Radio
WIFI/RF Radio
DESCRIPTIoN
No - Shows A-C class error codes. Yes - Shows only C class error
codes.
Set for Mile or Kilometer.
Set the stepper as S5x.
Power saving time for the self powered frame.
For non self powered frames only. Not used on this model.
Serial Number input is available for both the Console and Frame.
Use the number keys and UP / DOWN LEVEL keys to enter
Engineering Mode. Due to the limited LED characters, 2 layers are
used to enter the serial number. First Layer:
- PPPPP V
- PPPPP is the product name.
- V is the version. If the version is A, just leave this blank.
Second Layer
- YY MM nnnnn.
- YY is the year (11, 12).
- MM is the month (e.g. 08, 09, 10).
- nnnnn is the actual serial number.
Use the UP / DOWN LEVEL keys to navigate the layers and the
number keys to input the serial number. The product name is
dependent on the Machine Type setting.
For example, the console is CS18 with version A and the
manufactured date is 2011.08 with 98765. The frame is CS11 with
ver. B and the manufactured date is 2011.06 with 12345. Their serial
numbers are:
Console SN: CS18 1st layer, 110898765 2nd layer.
Frame SN: CS11B 1st layer, 110612345 2nd layer.
This sets the club ID for clubs using Asset Management.
Use up/down key to set offset resistance.
If there is no use of the machine over a period of time, the console
LEDs will turn off (go into ErP mode).
Manual setting that sets which outside TV will have audio through
the console audio ports.
Controls the default TV volume for entertainment wired through the
C-Safe port.
a. Input Default (DF : 15 / Range : 1 ~ 15)
b. Max Default (DF : 32 / Range : 1 ~ 32)
c. Output Default (DF : 13 / Range : 1 ~ Max)
Remote TV support a / b / c item. TV and PCTV only support c item.
To select AM output device by WIFI or RF Radio.