Use Of Patch Panel In Operators Room - Shure SZ 6104 User Manual

Conferencing and discussion systems dcs-lan switcher
Hide thumbs Also See for SZ 6104:
Table of Contents

Advertisement

DCS 6000 Digital Conference System
Redundancy switching with more than 16 languages:

Use of patch panel in Operators Room

On next page is a set-up with 3 meeting rooms
(several is possible) using a patch panel in a
central operators room for selecting the room
connections and audio output boxes for recording.
Note: Take care that screens of all patch
connectors are isolated from ground and each
other as faulty ground connections may cause
ground loops which again can result in corrupted
data communication of the chains. So use isolated
patch panels where the screens are isolated from
ground (plate and rack) and each other.
11
User Manual

Advertisement