HP StorageWorks 2000 Series Reference Manual page 280

Storageworks 2000 family modular smart array
Hide thumbs Also See for StorageWorks 2000 Series:
Table of Contents

Advertisement

60
Informational
61
Critical
62
Informational
65
Critical
67
Informational
68
Informational
69
Critical
71
Informational
72
Informational
A disk channel was reset from
another initiator or target.
A serious error, which might indicate
hardware failure, occurred while
communicating on the specified disk
channel. The controller will attempt
to recover.
A spare drive has failed.
An uncorrectable ECC error occurred
on the buffer memory on startup. The
controller is automatically restarted
and—if it was operating in active-
active mode (i.e., independent cache
performance mode was disabled)—its
cache data is restored from the
partner controller's cache.
The controller has identified a new
disk drive or group of disk drives that
constitute a vdisk and has taken
ownership of the vdisk. This can
happen when disk drives containing
data have been inserted from another
enclosure.
Controller is in a shut-down state.
Enclosure reported a general failure.
The controller has started or
completed failing over.
(Active-active environment)
After failover, recovery has started or
has completed.
• If the controller recovers, no
action is required.
• View other logged events to
determine other action to take.
Replace the failed drive.
Check the controller module or
expansion module for problems
such as not being fully inserted,
and for bad cables.

Advertisement

Table of Contents
loading

Table of Contents