Connecting The Domestic Hot Water Side - Viessmann VITOCELL 100-U Installation Instructions Manual

Vitocell 100-u type cvu dual-mode dhw cylinder with solar-set vitocell 100-w type cvu dual-mode dhw cylinder with solar-set
Hide thumbs Also See for VITOCELL 100-U:
Table of Contents

Advertisement

Connections on the heating water and solar sides
1. For heating water flow tempera-
tures in excess of 95 ºC:
Remove the cover bezels from the
heating water side pipe outlets
(bezels have l.h. threads).
2. Install the heat supply control unit.
3. Install the flow line with an incline
and fit an air vent valve at its high-
est point.

Connecting the domestic hot water side

&
For the DHW connection, observe
DIN 1988 and DIN 4753.
&
Connect the pipework with detach-
able fittings.
&
Seal connections that are not
required, with red brass caps.
&
Equip the DHW circulation line with
a DHW circulation pump and a
check valve.
&
Connection of the DHW circulation
pump:
– Connection to the boiler control
20
(cont.)
4. Only for heating water flow tem-
peratures in excess of 110 ºC:
Install a type-tested high limit
safety cut-out, if none has been
installed in the system. For this,
use a temperature limiter and a
high limit safety cut-out.
5. For solar heating systems:
Install an additional high limit
safety cut-out, if less than 40 litres
DHW volume is available per m
collector area (irrespective of the
collector type).
unit, if that is equipped with a
DHW circulation pump connec-
tion.
– Connection with a time switch, if
no DHW circulation pump connec-
tion is available on the boiler con-
trol unit.
– Connection via the time switch.
Permissible temperature:
Permissible operating
pressure:
Test pressure:
2
95 °C
10 bar
16 bar