Checking the anode connection and fitting the cover
C
A B
1.
Fig. 16
Protective magnesium anode
A
Earth cable
B
Note
Guide the thermometer leads through the groove in the
flange insulation.
Connecting the heating water side and solar side
Connect all pipework with detachable fittings.
■
Seal connections that are not required with caps.
■
■
Adjust the high limit safety cut-out so that the DHW
temperature in the DHW cylinder does not exceed
95
C.
º
16
2.
D
D
Thermometer lead
C
Type plate
D
Permissible temperatures
Solar side
Heating water side
Permissible operating pressure
Solar side
Heating water side
Test pressure
Solar side
Heating water side
3.
160 °C
160 °C
10 bar
(1 MPa)
10 bar
(1 MPa)
16 bar
(1.6 MPa)
16 bar
(1.6 MPa)